<?xml version="1.0" encoding="UTF-8" standalone="no"?><?xml-stylesheet href="../../stylesheet/spl.xsl" type="text/xsl"?><document xmlns="urn:hl7-org:v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:hl7-org:v3 https://www.accessdata.fda.gov/spl/schema/spl.xsd">
  <id root="78a0b514-481a-4ea9-8ec6-8b60acdf2158"/>
  <code code="34391-3" codeSystem="2.16.840.1.113883.6.1" displayName="HUMAN PRESCRIPTION DRUG LABEL"/>
  <title>These highlights do not include all the information needed to use TYVASO safely and effectively. See full prescribing information for TYVASO. <br/>
    <br/>TYVASO<sup>®</sup> (treprostinil) inhalation solution, for oral inhalation use <br/>Initial U.S. Approval: 2002</title>
  <effectiveTime value="20260414"/>
  <setId root="cbc31ab1-a80f-4b50-a3b1-39910b0fb609"/>
  <versionNumber value="32"/>
  <author>
    <time/>
    <assignedEntity>
      <representedOrganization>
        <id extension="965460025" root="1.3.6.1.4.1.519.1"/>
        <name>United Therapeutics Corporation</name>
        <assignedEntity>
          <assignedOrganization>
            <assignedEntity>
              <assignedOrganization>
                <id extension="015718364" root="1.3.6.1.4.1.519.1"/>
                <name>United Therapeutics Corporation</name>
              </assignedOrganization>
              <performance>
                <actDefinition>
                  <code code="C43360" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="MANUFACTURE"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
              <performance>
                <actDefinition>
                  <code code="C84731" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="PACK"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
              <performance>
                <actDefinition>
                  <code code="C84732" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="LABEL"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
            </assignedEntity>
            <assignedEntity>
              <assignedOrganization>
                <id extension="119301623" root="1.3.6.1.4.1.519.1"/>
                <name>United Therapeutics Corporation</name>
              </assignedOrganization>
              <performance>
                <actDefinition>
                  <code code="C25391" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="ANALYSIS"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
              <performance>
                <actDefinition>
                  <code code="C43360" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="MANUFACTURE"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
              <performance>
                <actDefinition>
                  <code code="C82401" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="API MANUFACTURE"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
              <performance>
                <actDefinition>
                  <code code="C84732" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="LABEL"/>
                  <product>
                    <manufacturedProduct classCode="MANU">
                      <manufacturedMaterialKind>
                        <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                      </manufacturedMaterialKind>
                    </manufacturedProduct>
                  </product>
                </actDefinition>
              </performance>
            </assignedEntity>
          </assignedOrganization>
        </assignedEntity>
      </representedOrganization>
    </assignedEntity>
  </author>
  <component>
    <structuredBody>
      <component>
        <section ID="DLDE">
          <id root="82013fd5-0878-4ba7-8de4-a267c1948872"/>
          <code code="48780-1" codeSystem="2.16.840.1.113883.6.1" displayName="SPL PRODUCT DATA ELEMENTS SECTION"/>
          <effectiveTime value="20220506"/>
          <subject>
            <manufacturedProduct>
              <manufacturedProduct>
                <code code="66302-206" codeSystem="2.16.840.1.113883.6.69"/>
                <name>TYVASO</name>
                <formCode code="C42944" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="INHALANT"/>
                <asEntityWithGeneric>
                  <genericMedicine>
                    <name>treprostinil</name>
                  </genericMedicine>
                </asEntityWithGeneric>
                <ingredient classCode="ACTIB">
                  <quantity>
                    <numerator unit="mg" value="1.74"/>
                    <denominator unit="mL" value="2.9"/>
                  </quantity>
                  <ingredientSubstance>
                    <code code="RUM6K67ESG" codeSystem="2.16.840.1.113883.4.9"/>
                    <name>TREPROSTINIL</name>
                    <activeMoiety>
                      <activeMoiety>
                        <code code="RUM6K67ESG" codeSystem="2.16.840.1.113883.4.9"/>
                        <name>TREPROSTINIL</name>
                      </activeMoiety>
                    </activeMoiety>
                  </ingredientSubstance>
                </ingredient>
                <ingredient classCode="IACT">
                  <quantity>
                    <numerator unit="mg" value="18.9"/>
                    <denominator unit="mL" value="2.9"/>
                  </quantity>
                  <ingredientSubstance>
                    <code code="451W47IQ8X" codeSystem="2.16.840.1.113883.4.9"/>
                    <name>SODIUM CHLORIDE</name>
                  </ingredientSubstance>
                </ingredient>
                <ingredient classCode="IACT">
                  <quantity>
                    <numerator unit="mg" value="18.3"/>
                    <denominator unit="mL" value="2.9"/>
                  </quantity>
                  <ingredientSubstance>
                    <code code="B22547B95K" codeSystem="2.16.840.1.113883.4.9"/>
                    <name>TRISODIUM CITRATE DIHYDRATE</name>
                  </ingredientSubstance>
                </ingredient>
                <ingredient classCode="IACT">
                  <quantity>
                    <numerator unit="mg" value="0.6"/>
                    <denominator unit="mL" value="2.9"/>
                  </quantity>
                  <ingredientSubstance>
                    <code code="55X04QC32I" codeSystem="2.16.840.1.113883.4.9"/>
                    <name>SODIUM HYDROXIDE</name>
                  </ingredientSubstance>
                </ingredient>
                <ingredient classCode="IACT">
                  <quantity>
                    <numerator unit="mg" value="11.7"/>
                    <denominator unit="mL" value="2.9"/>
                  </quantity>
                  <ingredientSubstance>
                    <code code="QTT17582CB" codeSystem="2.16.840.1.113883.4.9"/>
                    <name>HYDROCHLORIC ACID</name>
                  </ingredientSubstance>
                </ingredient>
                <ingredient classCode="IACT">
                  <ingredientSubstance>
                    <code code="059QF0KO0R" codeSystem="2.16.840.1.113883.4.9"/>
                    <name>WATER</name>
                  </ingredientSubstance>
                </ingredient>
                <asContent>
                  <quantity>
                    <numerator unit="mL" value="2.9"/>
                    <denominator value="1"/>
                  </quantity>
                  <containerPackagedProduct>
                    <code/>
                    <formCode code="C43165" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="AMPULE"/>
                    <asContent>
                      <quantity>
                        <numerator unit="1" value="28"/>
                        <denominator value="1"/>
                      </quantity>
                      <containerPackagedProduct>
                        <code/>
                        <formCode code="C43178" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="BOX"/>
                        <asContent>
                          <quantity>
                            <numerator unit="1" value="1"/>
                            <denominator value="1"/>
                          </quantity>
                          <containerPackagedProduct>
                            <code code="66302-206-01" codeSystem="2.16.840.1.113883.6.69"/>
                            <formCode code="C43197" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="KIT"/>
                          </containerPackagedProduct>
                          <subjectOf>
                            <marketingAct>
                              <code code="C53292" codeSystem="2.16.840.1.113883.3.26.1.1"/>
                              <statusCode code="active"/>
                              <effectiveTime>
                                <low value="20090814"/>
                              </effectiveTime>
                            </marketingAct>
                          </subjectOf>
                        </asContent>
                      </containerPackagedProduct>
                    </asContent>
                  </containerPackagedProduct>
                  <subjectOf>
                    <characteristic>
                      <code code="SPLCMBPRDTP" codeSystem="2.16.840.1.113883.1.11.19255"/>
                      <value code="C102842" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="TYPE 9: OTHER TYPE OF PART 3 COMBINATION PRODUCT (E.G., DRUG/DEVICE/BIOLOGICAL PRODUCT)" xsi:type="CV"/>
                    </characteristic>
                  </subjectOf>
                </asContent>
                <asContent>
                  <quantity>
                    <numerator unit="mL" value="2.9"/>
                    <denominator value="1"/>
                  </quantity>
                  <containerPackagedProduct>
                    <code/>
                    <formCode code="C43165" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="AMPULE"/>
                    <asContent>
                      <quantity>
                        <numerator unit="1" value="28"/>
                        <denominator value="1"/>
                      </quantity>
                      <containerPackagedProduct>
                        <code/>
                        <formCode code="C43178" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="BOX"/>
                        <asContent>
                          <quantity>
                            <numerator unit="1" value="1"/>
                            <denominator value="1"/>
                          </quantity>
                          <containerPackagedProduct>
                            <code code="66302-206-02" codeSystem="2.16.840.1.113883.6.69"/>
                            <formCode code="C43197" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="KIT"/>
                          </containerPackagedProduct>
                          <subjectOf>
                            <marketingAct>
                              <code code="C53292" codeSystem="2.16.840.1.113883.3.26.1.1"/>
                              <statusCode code="active"/>
                              <effectiveTime>
                                <low value="20090814"/>
                              </effectiveTime>
                            </marketingAct>
                          </subjectOf>
                        </asContent>
                      </containerPackagedProduct>
                    </asContent>
                  </containerPackagedProduct>
                  <subjectOf>
                    <characteristic>
                      <code code="SPLCMBPRDTP" codeSystem="2.16.840.1.113883.1.11.19255"/>
                      <value code="C102842" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="TYPE 9: OTHER TYPE OF PART 3 COMBINATION PRODUCT (E.G., DRUG/DEVICE/BIOLOGICAL PRODUCT)" xsi:type="CV"/>
                    </characteristic>
                  </subjectOf>
                </asContent>
                <asContent>
                  <quantity>
                    <numerator unit="mL" value="2.9"/>
                    <denominator value="1"/>
                  </quantity>
                  <containerPackagedProduct>
                    <code/>
                    <formCode code="C43165" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="AMPULE"/>
                    <asContent>
                      <quantity>
                        <numerator unit="1" value="4"/>
                        <denominator value="1"/>
                      </quantity>
                      <containerPackagedProduct>
                        <code code="66302-206-03" codeSystem="2.16.840.1.113883.6.69"/>
                        <formCode code="C43178" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="BOX"/>
                      </containerPackagedProduct>
                      <subjectOf>
                        <marketingAct>
                          <code code="C53292" codeSystem="2.16.840.1.113883.3.26.1.1"/>
                          <statusCode code="active"/>
                          <effectiveTime>
                            <low value="20090814"/>
                          </effectiveTime>
                        </marketingAct>
                      </subjectOf>
                    </asContent>
                  </containerPackagedProduct>
                  <subjectOf>
                    <characteristic>
                      <code code="SPLCMBPRDTP" codeSystem="2.16.840.1.113883.1.11.19255"/>
                      <value code="C102842" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="TYPE 9: OTHER TYPE OF PART 3 COMBINATION PRODUCT (E.G., DRUG/DEVICE/BIOLOGICAL PRODUCT)" xsi:type="CV"/>
                    </characteristic>
                  </subjectOf>
                </asContent>
                <asContent>
                  <quantity>
                    <numerator unit="mL" value="2.9"/>
                    <denominator value="1"/>
                  </quantity>
                  <containerPackagedProduct>
                    <code/>
                    <formCode code="C43165" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="AMPULE"/>
                    <asContent>
                      <quantity>
                        <numerator unit="1" value="4"/>
                        <denominator value="1"/>
                      </quantity>
                      <containerPackagedProduct>
                        <code/>
                        <formCode code="C43178" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="BOX"/>
                        <asContent>
                          <quantity>
                            <numerator unit="1" value="1"/>
                            <denominator value="1"/>
                          </quantity>
                          <containerPackagedProduct>
                            <code code="66302-206-04" codeSystem="2.16.840.1.113883.6.69"/>
                            <formCode code="C43197" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="KIT"/>
                          </containerPackagedProduct>
                          <subjectOf>
                            <marketingAct>
                              <code code="C53292" codeSystem="2.16.840.1.113883.3.26.1.1"/>
                              <statusCode code="active"/>
                              <effectiveTime>
                                <low value="20090814"/>
                              </effectiveTime>
                            </marketingAct>
                          </subjectOf>
                        </asContent>
                      </containerPackagedProduct>
                    </asContent>
                  </containerPackagedProduct>
                  <subjectOf>
                    <characteristic>
                      <code code="SPLCMBPRDTP" codeSystem="2.16.840.1.113883.1.11.19255"/>
                      <value code="C102842" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="TYPE 9: OTHER TYPE OF PART 3 COMBINATION PRODUCT (E.G., DRUG/DEVICE/BIOLOGICAL PRODUCT)" xsi:type="CV"/>
                    </characteristic>
                  </subjectOf>
                </asContent>
              </manufacturedProduct>
              <subjectOf>
                <approval>
                  <id extension="NDA022387" root="2.16.840.1.113883.3.150"/>
                  <code code="C73594" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="NDA"/>
                  <author>
                    <territorialAuthority>
                      <territory>
                        <code code="USA" codeSystem="2.16.840.1.113883.5.28"/>
                      </territory>
                    </territorialAuthority>
                  </author>
                </approval>
              </subjectOf>
              <subjectOf>
                <marketingAct>
                  <code code="C53292" codeSystem="2.16.840.1.113883.3.26.1.1"/>
                  <statusCode code="active"/>
                  <effectiveTime>
                    <low value="20090814"/>
                  </effectiveTime>
                </marketingAct>
              </subjectOf>
              <consumedIn>
                <substanceAdministration>
                  <routeCode code="C38288" codeSystem="2.16.840.1.113883.3.26.1.1" displayName="ORAL"/>
                </substanceAdministration>
              </consumedIn>
            </manufacturedProduct>
          </subject>
        </section>
      </component>
      <component>
        <section>
          <id root="07787581-aa2a-44d3-9ca3-74e66dc46b7e"/>
          <code code="43683-2" codeSystem="2.16.840.1.113883.6.1" displayName="RECENT MAJOR CHANGES SECTION"/>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <table styleCode="Noautorules" width="100%">
                  <col align="left" valign="top" width="75%"/>
                  <col align="right" valign="top" width="25%"/>
                  <tbody>
                    <tr>
                      <td>Warnings and Precautions (<linkHtml href="#S5.4">5.4</linkHtml>)</td>
                      <td>05/2022</td>
                    </tr>
                  </tbody>
                </table>
              </text>
            </highlight>
          </excerpt>
        </section>
      </component>
      <component>
        <section ID="S1">
          <id root="6f282bf8-c340-41cd-9180-5d5457f43dc2"/>
          <code code="34067-9" codeSystem="2.16.840.1.113883.6.1" displayName="INDICATIONS &amp; USAGE SECTION"/>
          <title>1 INDICATIONS AND USAGE</title>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <paragraph>Tyvaso is a prostacyclin mimetic indicated for the treatment of:</paragraph>
                <list listType="unordered" styleCode="disc">
                  <item>Pulmonary arterial hypertension (PAH; WHO Group 1) to improve exercise ability. Studies establishing effectiveness predominately included patients with NYHA Functional Class III symptoms and etiologies of idiopathic or heritable PAH (56%) or PAH associated with connective tissue diseases (33%). (<linkHtml href="#S1.1">1.1</linkHtml>)</item>
                  <item>Pulmonary hypertension associated with interstitial lung disease (PH-ILD; WHO Group 3) to improve exercise ability. The study establishing effectiveness predominately included patients with etiologies of idiopathic interstitial pneumonia (IIP) (45%) inclusive of idiopathic pulmonary fibrosis (IPF), combined pulmonary fibrosis and emphysema (CPFE) (25%), and WHO Group 3 connective tissue disease (22%). (<linkHtml href="#S1.2">1.2</linkHtml>)</item>
                </list>
              </text>
            </highlight>
          </excerpt>
          <component>
            <section ID="S1.1">
              <id root="6894c9ef-a06a-4a93-8c1a-1ee9dd71bee4"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>1.1 Pulmonary Arterial Hypertension</title>
              <text>
                <paragraph>Tyvaso is indicated for the treatment of pulmonary arterial hypertension (PAH; WHO Group 1) to improve exercise ability. Studies establishing effectiveness predominately included patients with NYHA Functional Class III symptoms and etiologies of idiopathic or heritable PAH (56%) or PAH associated with connective tissue diseases (33%).</paragraph>
                <paragraph>The effects diminish over the minimum recommended dosing interval of 4 hours; treatment timing can be adjusted for planned activities.</paragraph>
                <paragraph>While there are long-term data on use of treprostinil by other routes of administration, nearly all controlled clinical experience with inhaled treprostinil has been on a background of bosentan (an endothelin receptor antagonist) or sildenafil (a phosphodiesterase type 5 inhibitor). The controlled clinical experience was limited to 12 weeks in duration <content styleCode="italics">[see <linkHtml href="#S14">Clinical Studies (14)</linkHtml>]</content>.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S1.2">
              <id root="10e153ea-3792-4846-9fc0-42951a7113bf"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>1.2 Pulmonary Hypertension Associated with ILD</title>
              <text>
                <paragraph>									Tyvaso is indicated for the treatment of pulmonary hypertension associated with interstitial lung disease (PH-ILD; WHO Group 3) to improve exercise ability. The study establishing effectiveness predominately included patients with etiologies of idiopathic interstitial pneumonia (IIP) (45%) inclusive of idiopathic pulmonary fibrosis (IPF), combined pulmonary fibrosis and emphysema (CPFE) (25%), and WHO Group 3 connective tissue disease (22%) <content styleCode="italics">[see <linkHtml href="#S14">Clinical Studies (14)</linkHtml>]</content>. 								</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S2">
          <id root="cfbf67b3-5673-4bb1-be8d-a5da176e1487"/>
          <code code="34068-7" codeSystem="2.16.840.1.113883.6.1" displayName="DOSAGE &amp; ADMINISTRATION SECTION"/>
          <title>2 DOSAGE AND ADMINISTRATION</title>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <list listType="unordered" styleCode="disc">
                  <item>Use only with the Tyvaso Inhalation System. (<linkHtml href="#S2.1">2.1</linkHtml>)</item>
                  <item>Administer undiluted, as supplied. A single breath of Tyvaso delivers approximately 6 mcg of treprostinil. (<linkHtml href="#S2.1">2.1</linkHtml>)</item>
                  <item>Administer in 4 separate treatment sessions each day approximately 4 hours apart, during waking hours. (<linkHtml href="#S2.1">2.1</linkHtml>)</item>
                  <item>Initial dosage: 3 breaths (18 mcg) per treatment session. If 3 breaths are not tolerated, reduce to 1 or 2 breaths. (<linkHtml href="#S2.1">2.1</linkHtml>)</item>
                  <item>Dosage should be increased by an additional 3 breaths per treatment session at approximately 1- to 2-week intervals, if tolerated. (<linkHtml href="#S2.1">2.1</linkHtml>)</item>
                  <item>Titrate to target maintenance doses of 9 to 12 breaths per treatment session, 4 times daily. (<linkHtml href="#S2.1">2.1</linkHtml>)</item>
                </list>
              </text>
            </highlight>
          </excerpt>
          <component>
            <section ID="S2.1">
              <id root="af50ddbd-96af-4e7c-85bd-196e12f0d077"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>2.1 Usual Dosage in Adults</title>
              <text>
                <paragraph>Tyvaso is intended for oral inhalation using the Tyvaso Inhalation System, which consists of an ultrasonic, pulsed delivery device and its accessories.</paragraph>
                <paragraph>Tyvaso is dosed in 4 separate, equally spaced treatment sessions per day, during waking hours. Each treatment session will take 2 to 3 minutes. The treatment sessions should be approximately 4 hours apart.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
              <component>
                <section>
                  <id root="cc60e54d-ece8-4bab-a6d6-d5188e0f2524"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="bold italics">Initial Dosage:</content>
                    </paragraph>
                    <paragraph>Therapy should begin with 3 breaths of Tyvaso (18 mcg of treprostinil) per treatment session 4 times daily. If 3 breaths are not tolerated, reduce to 1 or 2 breaths and subsequently increase to 3 breaths, as tolerated.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
              <component>
                <section>
                  <id root="06209f52-c0f0-4549-9484-a63488060b95"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="bold italics">Maintenance Dosage:</content>
                    </paragraph>
                    <paragraph>Dosage should be increased by an additional 3 breaths per treatment session, 4 times daily at approximately 1- to 2-week intervals. Studies establishing effectiveness in patients with PAH and PH-ILD have used target doses of 9 to 12 breaths per treatment session, 4 times daily. If adverse effects preclude titration to target dose, Tyvaso should be continued at the highest tolerated dose.</paragraph>
                    <paragraph>If a scheduled treatment session is missed or interrupted, therapy should be resumed as soon as possible at the usual dose.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
            </section>
          </component>
          <component>
            <section ID="S2.2">
              <id root="fb278454-ebad-4ab0-a34c-34fe85631da9"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>2.2 Administration</title>
              <text>
                <paragraph>Tyvaso must be used only with the Tyvaso Inhalation System. Patients should follow the instructions for use for operation of the Tyvaso Inhalation System and for daily cleaning of the device components after the last treatment session of the day. To avoid potential interruptions in drug delivery because of equipment malfunction, patients should have access to a back-up Tyvaso Inhalation System device.</paragraph>
                <paragraph>Do not mix Tyvaso with other medications in the Tyvaso Inhalation System. Compatibility of Tyvaso with other medications has not been studied.</paragraph>
                <paragraph>The Tyvaso Inhalation System should be prepared for use each day according to the instructions for use. One ampule of Tyvaso contains a sufficient volume of medication for all 4 treatment sessions in a single day. Prior to the first treatment session, the patient should twist the top off a single Tyvaso ampule and squeeze the entire contents into the medicine cup. Between each of the 4 daily treatment sessions, the device should be capped and stored upright with the remaining medication inside.</paragraph>
                <paragraph>At the end of each day, the medicine cup and any remaining medication must be discarded. The device must be cleaned each day according to the instructions for use.</paragraph>
                <paragraph>Avoid skin or eye contact with Tyvaso solution. Do not orally ingest the Tyvaso solution.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S3">
          <id root="b582c047-05e7-48e3-a411-52dfa3b6e9de"/>
          <code code="43678-2" codeSystem="2.16.840.1.113883.6.1" displayName="DOSAGE FORMS &amp; STRENGTHS SECTION"/>
          <title>3 DOSAGE FORMS AND STRENGTHS</title>
          <text>
            <paragraph>Sterile solution for oral inhalation: 2.9 mL ampule containing 1.74 mg of treprostinil (0.6 mg per mL).</paragraph>
          </text>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <paragraph>Sterile solution for oral inhalation: 2.9 mL ampule containing 1.74 mg treprostinil (0.6 mg per mL). (<linkHtml href="#S3">3</linkHtml>)</paragraph>
              </text>
            </highlight>
          </excerpt>
        </section>
      </component>
      <component>
        <section ID="S4">
          <id root="7db7151b-ceac-4a67-94d9-017873ee7c31"/>
          <code code="34070-3" codeSystem="2.16.840.1.113883.6.1" displayName="CONTRAINDICATIONS SECTION"/>
          <title>4 CONTRAINDICATIONS</title>
          <text>
            <paragraph>None.</paragraph>
          </text>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <paragraph>None. (<linkHtml href="#S4">4</linkHtml>)</paragraph>
              </text>
            </highlight>
          </excerpt>
        </section>
      </component>
      <component>
        <section ID="S5">
          <id root="40009817-17a4-4561-bae3-a86226b1ce61"/>
          <code code="43685-7" codeSystem="2.16.840.1.113883.6.1" displayName="WARNINGS AND PRECAUTIONS SECTION"/>
          <title>5 WARNINGS AND PRECAUTIONS</title>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <list listType="unordered" styleCode="disc">
                  <item>Tyvaso may cause symptomatic hypotension. (<linkHtml href="#S5.1">5.1</linkHtml>)</item>
                  <item>Tyvaso inhibits platelet aggregation and increases the risk of bleeding. (<linkHtml href="#S5.2">5.2</linkHtml>)</item>
                  <item>Tyvaso dosage adjustments may be necessary if inhibitors or inducers of CYP2C8 are added or withdrawn. (<linkHtml href="#S5.3">5.3</linkHtml>, <linkHtml href="#S7.3">7.3</linkHtml>)</item>
                  <item>May cause bronchospasm: Patients with a history of hyperreactive airway disease may be more sensitive. (<linkHtml href="#S5.4">5.4</linkHtml>)</item>
                </list>
              </text>
            </highlight>
          </excerpt>
          <component>
            <section ID="S5.1">
              <id root="f16c0bbe-4be2-41be-a77a-7fb9fa6f9fff"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>5.1 Risk of Symptomatic Hypotension</title>
              <text>
                <paragraph>Treprostinil is a pulmonary and systemic vasodilator. In patients with low systemic arterial pressure, treatment with Tyvaso may produce symptomatic hypotension.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S5.2">
              <id root="3006a196-de04-4668-8304-993ab99d6ba9"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>5.2 Risk of Bleeding</title>
              <text>
                <paragraph>Tyvaso inhibits platelet aggregation and increases the risk of bleeding.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S5.3">
              <id root="97b706d3-cae6-4e15-a817-53e024612b9b"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>5.3 Effect of Other Drugs on Treprostinil</title>
              <text>
                <paragraph>Co-administration of a cytochrome P450 (CYP) 2C8 enzyme inhibitor (e.g., gemfibrozil) may increase exposure (both C<sub>max</sub> and AUC) to treprostinil. Co-administration of a CYP2C8 enzyme inducer (e.g., rifampin) may decrease exposure to treprostinil. Increased exposure is likely to increase adverse events associated with treprostinil administration, whereas decreased exposure is likely to reduce clinical effectiveness <content styleCode="italics">[see <linkHtml href="#S7.3">Drug Interactions (7.3)</linkHtml> and <linkHtml href="#S12.3">Clinical Pharmacology (12.3)</linkHtml>]</content>.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S5.4">
              <id root="1a2d7be4-fb8d-4123-a444-5e93ccfcd088"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>5.4 Bronchospasm</title>
              <text>
                <paragraph>
                  <content styleCode="xmChange">Like other inhaled prostaglandins, Tyvaso may cause acute bronchospasm. Patients with asthma or chronic obstructive pulmonary disease (COPD), or other bronchial hyperreactivity, are at increased risk for bronchospasm. Ensure that such patients are treated optimally for reactive airway disease prior to and during treatment with Tyvaso Inhalation Solution.</content>
                </paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S6">
          <id root="69c5c707-7d74-4763-bbbd-7ece501a0cf9"/>
          <code code="34084-4" codeSystem="2.16.840.1.113883.6.1" displayName="ADVERSE REACTIONS SECTION"/>
          <title>6 ADVERSE REACTIONS</title>
          <text>
            <paragraph>The following potential adverse reactions are described in Warnings and Precautions (5):</paragraph>
            <list listType="unordered">
              <item>
                <caption>-</caption>Decrease in systemic blood pressure <content styleCode="italics">[see <linkHtml href="#S5.1">Warnings and Precautions (5.1)</linkHtml>]</content>.</item>
              <item>
                <caption>-</caption>Bleeding <content styleCode="italics">[see <linkHtml href="#S5.2">Warnings and Precautions (5.2)</linkHtml>]</content>.</item>
            </list>
          </text>
          <effectiveTime value="20220506"/>
          <excerpt>
            <highlight>
              <text>
                <paragraph>Most common adverse reactions (≥4%) are cough, headache, nausea, dizziness, flushing, throat irritation, pharyngolaryngeal pain, diarrhea, and syncope. (<linkHtml href="#S6">6</linkHtml>)</paragraph>
                <br/>
                <paragraph>
                  <content styleCode="bold">To report SUSPECTED ADVERSE REACTIONS, contact United Therapeutics Corp. at 1-866-458-6479 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch.</content>
                </paragraph>
              </text>
            </highlight>
          </excerpt>
          <component>
            <section ID="S6.1">
              <id root="81e3bab1-f360-4d69-b83d-eebbfb523d89"/>
              <code code="90374-0" codeSystem="2.16.840.1.113883.6.1" displayName="CLINICAL TRIALS EXPERIENCE SECTION"/>
              <title>6.1 Clinical Trials Experience</title>
              <text>
                <paragraph>Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
              <component>
                <section>
                  <id root="53b2ec15-474c-4433-9530-49656766b8bc"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="underline">Pulmonary Arterial Hypertension</content>
                    </paragraph>
                    <paragraph>In a 12-week, placebo-controlled study (TRIUMPH I) of 235 patients with PAH (WHO Group 1 and nearly all NYHA Functional Class III), the most commonly reported adverse reactions on Tyvaso included cough and throat irritation, headache, gastrointestinal effects, muscle, jaw or bone pain, dizziness, flushing, and syncope. Table 1 lists the adverse reactions that occurred at a rate of at least 4% and were more frequent in patients treated with Tyvaso than with placebo.</paragraph>
                    <table ID="table1" width="75%">
                      <caption>Table 1:	Adverse Events in ≥4% of PAH Patients Receiving Tyvaso and More Frequent<footnote>More than 3% greater than placebo</footnote> than Placebo in TRIUMPH I</caption>
                      <col align="center" valign="middle" width="50%"/>
                      <col align="center" valign="middle" width="25%"/>
                      <col align="center" valign="middle" width="25%"/>
                      <thead>
                        <tr>
                          <th rowspan="2" styleCode="Lrule Rrule">Adverse Event</th>
                          <th colspan="2" styleCode="Botrule Rrule">Treatment<br/> n (%)</th>
                        </tr>
                        <tr>
                          <th styleCode="Rrule">Tyvaso<br/>n=115</th>
                          <th styleCode="Rrule">Placebo<br/>n=120</th>
                        </tr>
                      </thead>
                      <tbody>
                        <tr styleCode="Botrule">
                          <td styleCode="Lrule Rrule">Cough</td>
                          <td styleCode="Rrule">62 (54)</td>
                          <td styleCode="Rrule">35 (29)</td>
                        </tr>
                        <tr styleCode="Botrule">
                          <td styleCode="Lrule Rrule">Headache</td>
                          <td styleCode="Rrule">47 (41)</td>
                          <td styleCode="Rrule">27 (23)</td>
                        </tr>
                        <tr styleCode="Botrule">
                          <td styleCode="Lrule Rrule">Throat Irritation / Pharyngolaryngeal Pain</td>
                          <td styleCode="Rrule">29 (25)</td>
                          <td styleCode="Rrule">17 (14)</td>
                        </tr>
                        <tr styleCode="Botrule">
                          <td styleCode="Lrule Rrule">Nausea</td>
                          <td styleCode="Rrule">22 (19)</td>
                          <td styleCode="Rrule">13 (11)</td>
                        </tr>
                        <tr styleCode="Botrule">
                          <td styleCode="Lrule Rrule">Flushing</td>
                          <td styleCode="Rrule">17 (15)</td>
                          <td styleCode="Rrule">1 (&lt;1)</td>
                        </tr>
                        <tr>
                          <td styleCode="Lrule Rrule">Syncope</td>
                          <td styleCode="Rrule">7 (6)</td>
                          <td styleCode="Rrule">1 (&lt;1)</td>
                        </tr>
                      </tbody>
                    </table>
                    <paragraph>The safety of Tyvaso was also studied in a long-term, open-label extension study in which 206 patients were dosed for a mean duration of 2.3 years, with a maximum exposure of 5.4 years. Eighty-nine percent (89%) of patients achieved the target dose of 9 breaths, 4 times daily. Forty-two percent (42%) achieved a dose of 12 breaths, 4 times daily. The adverse events during this chronic dosing study were qualitatively similar to those observed in the 12-week placebo-controlled trial.</paragraph>
                    <paragraph>In a prospective, observational study comparing patients taking Tyvaso (958 patient-years of exposure) and a control group (treatment with other approved therapies for PAH; 1094 patient-years), Tyvaso was associated with a higher rate of cough (16.2 vs. 10.9 per 100 patient-years), throat irritation (4.5 vs. 1.2 per 100 pt-years), nasal discomfort (2.6 vs. 1.3 per 100 pt-years), and hemoptysis (2.5 vs. 1.3 per 100 pt-years) compared to the control group.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
              <component>
                <section>
                  <id root="6eeed5d2-0554-499a-82bb-141398eaf061"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="underline">Pulmonary Hypertension Associated with ILD</content>
                    </paragraph>
                    <paragraph>In a 16-week, placebo-controlled study (INCREASE) of 326 patients with PH-ILD (WHO Group 3), adverse reactions were similar to the experience in studies of PAH.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
            </section>
          </component>
          <component>
            <section ID="S6.2">
              <id root="eb5fec50-1245-4204-8959-baac4b1e9a38"/>
              <code code="90375-7" codeSystem="2.16.840.1.113883.6.1" displayName="POSTMARKETING EXPERIENCE SECTION"/>
              <title>6.2 Post-Marketing Experience</title>
              <text>
                <paragraph>The adverse reaction of angioedema has been identified during the post-approval use of Tyvaso. Because this reaction is reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate the frequency or establish a causal relationship to drug exposure.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S7">
          <id root="030d5e82-3cd5-4a6f-8c63-7b5a3ede0bda"/>
          <code code="34073-7" codeSystem="2.16.840.1.113883.6.1" displayName="DRUG INTERACTIONS SECTION"/>
          <title>7 DRUG INTERACTIONS</title>
          <effectiveTime value="20220506"/>
          <component>
            <section ID="S7.1">
              <id root="aee0c725-59a6-41cc-a702-8d0da612f330"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>7.1 Bosentan</title>
              <text>
                <paragraph>In a human pharmacokinetic study conducted with bosentan (250 mg/day) and an oral formulation of treprostinil (treprostinil diolamine), no pharmacokinetic interactions between treprostinil and bosentan were observed.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S7.2">
              <id root="e5c2d633-c20b-44b2-865c-43893eadb46d"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>7.2 Sildenafil</title>
              <text>
                <paragraph>In a human pharmacokinetic study conducted with sildenafil (60 mg/day) and an oral formulation of treprostinil (treprostinil diolamine), no pharmacokinetic interactions between treprostinil and sildenafil were observed.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S7.3">
              <id root="7490e156-0f86-4304-ba0c-86a322381d41"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>7.3 Effect of Cytochrome P450 Inhibitors and Inducers</title>
              <text>
                <paragraph>
                  <content styleCode="italics">In vitro</content> studies of human hepatic microsomes showed that treprostinil does not inhibit cytochrome P450 (CYP) isoenzymes CYP1A2, CYP2A6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, and CYP3A. Additionally, treprostinil does not induce cytochrome P450 isoenzymes CYP1A2, CYP2B6, CYP2C9, CYP2C19, and CYP3A.</paragraph>
                <paragraph>Human pharmacokinetic studies with an oral formulation of treprostinil (treprostinil diolamine) indicated that co-administration of the cytochrome P450 (CYP) 2C8 enzyme inhibitor, gemfibrozil, increases exposure (both C<sub>max</sub> and AUC) to treprostinil. Co-administration of the CYP2C8 enzyme inducer, rifampin, decreases exposure to treprostinil. It is unclear if the safety and efficacy of treprostinil by the inhalation route are altered by inhibitors or inducers of CYP2C8 <content styleCode="italics">[see <linkHtml href="#S5.3">Warnings and Precautions (5.3)</linkHtml>]</content>.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S7.4">
              <id root="fd285e33-3ace-4a74-a8fb-c88bdcb5293d"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>7.4 Effect of Other Drugs on Treprostinil</title>
              <text>
                <paragraph>Drug interaction studies have been carried out with treprostinil (oral or subcutaneous) co-administered with acetaminophen (4 g/day), warfarin (25 mg/day), and fluconazole (200 mg/day), respectively, in healthy volunteers. These studies did not show a clinically significant effect on the pharmacokinetics of treprostinil. Treprostinil does not affect the pharmacokinetics or pharmacodynamics of warfarin. The pharmacokinetics of R- and S- warfarin and the international normalized ratio (INR) in healthy subjects given a single 25 mg dose of warfarin were unaffected by continuous subcutaneous infusion of treprostinil at an infusion rate of 10 ng/kg/min.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S8">
          <id root="94c3fc37-74bd-47c9-b458-26c9fa843f4a"/>
          <code code="43684-0" codeSystem="2.16.840.1.113883.6.1" displayName="USE IN SPECIFIC POPULATIONS SECTION"/>
          <title>8 USE IN SPECIFIC POPULATIONS</title>
          <effectiveTime value="20220506"/>
          <component>
            <section ID="S8.1">
              <id root="46227742-71d7-47e7-8fcc-2163db11fff1"/>
              <code code="42228-7" codeSystem="2.16.840.1.113883.6.1" displayName="PREGNANCY SECTION"/>
              <title>8.1 Pregnancy</title>
              <effectiveTime value="20220506"/>
              <component>
                <section>
                  <id root="32faa123-c623-4dae-8502-9f7c6e98606d"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="underline">Risk Summary</content>
                    </paragraph>
                    <paragraph>Limited case reports of treprostinil use in pregnant women are insufficient to inform a drug-associated risk of adverse developmental outcomes. However, there are risks to the mother and the fetus associated with pulmonary arterial hypertension <content styleCode="italics">(see <linkHtml href="#cc">Clinical Considerations</linkHtml>)</content>. In animal studies, no adverse reproductive and developmental effects were seen for treprostinil at ≥9 and ≥145 times the human exposure when based on C<sub>max</sub> and AUC, respectively, following a single treprostinil dose of 54 mcg.</paragraph>
                    <paragraph>The estimated background risk of major birth defects and miscarriage for the indicated populations is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2 to 4% and 15 to 20%, respectively.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
              <component>
                <section ID="cc">
                  <id root="58eb8fb2-7897-4d61-b01a-1a8f8c81ef30"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="underline">Clinical Considerations</content>
                    </paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                  <component>
                    <section>
                      <id root="7bff8962-4949-4e0d-a703-9409f47b1e48"/>
                      <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                      <text>
                        <paragraph>
                          <content styleCode="italics">Disease-associated maternal and embryo-fetal risk</content>
                        </paragraph>
                        <paragraph>Pulmonary arterial hypertension is associated with an increased risk of maternal and fetal mortality.</paragraph>
                      </text>
                      <effectiveTime value="20220506"/>
                    </section>
                  </component>
                </section>
              </component>
              <component>
                <section>
                  <id root="18872761-ab8d-4451-8694-d2cb66fdf99e"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="underline">Data</content>
                    </paragraph>
                    <paragraph>Animal reproduction studies have been conducted with treprostinil via continuous subcutaneous administration and with treprostinil diolamine administered orally. In studies with orally administered treprostinil diolamine, no adverse effect doses for fetal viability/growth, fetal development (teratogenicity), and postnatal development were determined in rats. In pregnant rats, no evidence of harm to the fetus was observed following oral administration of treprostinil diolamine at the highest dose tested (20 mg/kg/day), which represents about 154 and 1479 times the human exposure, when based on C<sub>max</sub> and AUC, respectively, following a single Tyvaso dose of 54 mcg. In pregnant rabbits, external fetal and soft tissue malformations and fetal skeletal malformation occurred. The dose at which no adverse effects were seen (0.5 mg/kg/day) represents about 9 and 145 times the human exposure, when based on C<sub>max</sub> and AUC, respectively, following a single Tyvaso dose of 54 mcg. No treprostinil treatment-related effects on labor and delivery were seen in animal studies. Animal reproduction studies are not always predictive of human response. </paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
            </section>
          </component>
          <component>
            <section ID="S8.2">
              <id root="240ffd8e-6c28-47b7-82c8-369e21ffcb94"/>
              <code code="77290-5" codeSystem="2.16.840.1.113883.6.1" displayName="LACTATION SECTION"/>
              <title>8.2 Lactation</title>
              <effectiveTime value="20220506"/>
              <component>
                <section>
                  <id root="be04ec6c-ee40-4c25-a8be-157f427f6a30"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="underline">Risk Summary</content>
                    </paragraph>
                    <paragraph>There are no data on the presence of treprostinil in human milk, the effects on the breastfed infant, or the effects on milk production.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
            </section>
          </component>
          <component>
            <section ID="S8.4">
              <id root="7a09876e-650c-4860-996e-f073dc9a2c1b"/>
              <code code="34081-0" codeSystem="2.16.840.1.113883.6.1" displayName="PEDIATRIC USE SECTION"/>
              <title>8.4 Pediatric Use</title>
              <text>
                <paragraph>Safety and effectiveness in pediatric patients have not been established. Clinical studies of Tyvaso did not include patients younger than 18 years to determine whether they respond differently from older patients.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S8.5">
              <id root="16c1fbe2-8175-4dc8-ba91-2a1c6a275431"/>
              <code code="34082-8" codeSystem="2.16.840.1.113883.6.1" displayName="GERIATRIC USE SECTION"/>
              <title>8.5 Geriatric Use</title>
              <text>
                <paragraph>Across clinical studies used to establish the effectiveness of Tyvaso in patients with PAH and PH-ILD, 268 (47.8%) patients aged 65 years and over were enrolled. The treatment effects and safety profile observed in geriatric patients were similar to younger patients. In general, dose selection for an elderly patient should be cautious, reflecting the greater frequency of hepatic, renal, or cardiac dysfunction, and of concomitant diseases or other drug therapy.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S8.6">
              <id root="c2b69114-eb08-4ccc-b8b3-da62e1837773"/>
              <code code="88829-7" codeSystem="2.16.840.1.113883.6.1" displayName="HEPATIC IMPAIRMENT SUBSECTION"/>
              <title>8.6 Patients with Hepatic Insufficiency</title>
              <text>
                <paragraph>Plasma clearance of treprostinil, delivered subcutaneously, was reduced up to 80% in subjects with mild-to-moderate hepatic insufficiency. Uptitrate slowly when treating patients with hepatic insufficiency because of the risk of an increase in systemic exposure which may lead to an increase in dose-dependent adverse effects. Treprostinil has not been studied in patients with severe hepatic insufficiency <content styleCode="italics">[see <linkHtml href="#S12.3">Clinical Pharmacology (12.3)</linkHtml>]</content>.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S8.7">
              <id root="d45c64dc-b197-44f2-a0a8-74bbd9d49b64"/>
              <code code="88828-9" codeSystem="2.16.840.1.113883.6.1" displayName="RENAL IMPAIRMENT SUBSECTION"/>
              <title>8.7 Patients with Renal Impairment</title>
              <text>
                <paragraph>No dose adjustments are required in patients with renal impairment. Treprostinil is not cleared by dialysis <content styleCode="italics">[see <linkHtml href="#S12.3">Clinical Pharmacology (12.3)</linkHtml>]</content>.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S10">
          <id root="d0e02233-c105-4929-aba4-22a785a21877"/>
          <code code="34088-5" codeSystem="2.16.840.1.113883.6.1" displayName="OVERDOSAGE SECTION"/>
          <title>10 OVERDOSAGE</title>
          <text>
            <paragraph>In general, symptoms of overdose with Tyvaso include flushing, headache, hypotension, nausea, vomiting, and diarrhea. Provide general supportive care until the symptoms of overdose have resolved.</paragraph>
          </text>
          <effectiveTime value="20220506"/>
        </section>
      </component>
      <component>
        <section ID="S11">
          <id root="d97c4d93-8492-4d40-a46a-062b52a41f93"/>
          <code code="34089-3" codeSystem="2.16.840.1.113883.6.1" displayName="DESCRIPTION SECTION"/>
          <title>11 DESCRIPTION</title>
          <text>
            <paragraph>Tyvaso is a sterile formulation of treprostinil, a prostacyclin mimetic, intended for administration by oral inhalation using the Tyvaso Inhalation System. Tyvaso is supplied in 2.9 mL low density polyethylene (LDPE) ampules, containing 1.74 mg treprostinil (0.6 mg/mL). Each ampule also contains 18.9 mg sodium chloride, 18.3 mg sodium citrate dihydrate, 0.58 mg sodium hydroxide, 11.7 mg 1 N hydrochloric acid, and water for injection. Sodium hydroxide and hydrochloric acid may be added to adjust pH between 6.0 and 7.2.</paragraph>
            <paragraph>Treprostinil is (1<content styleCode="italics">R</content>,2<content styleCode="italics">R</content>,3a<content styleCode="italics">S</content>,9a<content styleCode="italics">S</content>)-[[2,3,3a,4,9,9a-hexahydro-2-hydroxy-1-[(3<content styleCode="italics">S</content>)-3-hydroxyoctyl]-1<content styleCode="italics">H</content>-benz[<content styleCode="italics">f</content>]inden-5-yl]oxy]acetic acid. Treprostinil has a molecular weight of 390.52 and a molecular formula of C<sub>23</sub>H<sub>34</sub>O<sub>5</sub>.</paragraph>
            <paragraph>The structural formula of treprostinil is:</paragraph>
            <renderMultiMedia referencedObject="MM1"/>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM1">
              <text>Chemical Structure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-01.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
      <component>
        <section ID="S12">
          <id root="e729f00e-1190-4d17-b57a-471a11b6b5c8"/>
          <code code="34090-1" codeSystem="2.16.840.1.113883.6.1" displayName="CLINICAL PHARMACOLOGY SECTION"/>
          <title>12 CLINICAL PHARMACOLOGY</title>
          <effectiveTime value="20220506"/>
          <component>
            <section ID="S12.1">
              <id root="291bdd3f-e847-446e-82eb-64202a8f1fef"/>
              <code code="43679-0" codeSystem="2.16.840.1.113883.6.1" displayName="MECHANISM OF ACTION SECTION"/>
              <title>12.1 Mechanism of Action</title>
              <text>
                <paragraph>Treprostinil is a prostacyclin analogue. The major pharmacologic actions of treprostinil are direct vasodilation of pulmonary and systemic arterial vascular beds and inhibition of platelet aggregation.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S12.2">
              <id root="5cc1fcaa-4ee4-474e-835a-cd7a10543933"/>
              <code code="43681-6" codeSystem="2.16.840.1.113883.6.1" displayName="PHARMACODYNAMICS SECTION"/>
              <title>12.2 Pharmacodynamics</title>
              <text>
                <paragraph>In a clinical trial of 240 healthy volunteers, single doses of Tyvaso 54 mcg (the target maintenance dose per session) and 84 mcg (supratherapeutic inhalation dose) prolonged the corrected QTc interval by approximately 10 ms. The QTc effect dissipated rapidly as the concentration of treprostinil decreased.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S12.3">
              <id root="4d436091-2bbb-4c4c-8c0c-d6227fd8cb7a"/>
              <code code="43682-4" codeSystem="2.16.840.1.113883.6.1" displayName="PHARMACOKINETICS SECTION"/>
              <title>12.3 Pharmacokinetics</title>
              <text>
                <paragraph>Pharmacokinetic information for single doses of inhaled treprostinil was obtained in healthy volunteers in 3 separate studies. Treprostinil systemic exposure (AUC and C<sub>max</sub>) post-inhalation was shown to be proportional to the doses administered (18 mcg to 90 mcg).</paragraph>
              </text>
              <effectiveTime value="20220506"/>
              <component>
                <section>
                  <id root="37391a23-c66f-4203-be91-12eeb8866217"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="bold">Absorption</content>
                    </paragraph>
                    <paragraph>In a 3-period crossover study, the bioavailability of 2 single doses of Tyvaso (18 mcg and 36 mcg) was compared with that of intravenous treprostinil in 18 healthy volunteers. Mean estimates of the absolute systemic bioavailability of treprostinil after inhalation were approximately 64% (18 mcg) and 72% (36 mcg).</paragraph>
                    <paragraph>Treprostinil plasma exposure data were obtained from 2 studies at the target maintenance dose, 54 mcg. The mean C<sub>max</sub> at the target dose was 0.91 and 1.32 ng/mL with corresponding mean T<sub>max</sub> of 0.25 and 0.12 hr, respectively. The mean AUC for the 54-mcg dose was 0.81 and 0.97 hr∙ng/mL, respectively.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
              <component>
                <section>
                  <id root="fcd2a1c9-ab84-44b4-b8c6-376181b3740b"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="bold">Distribution</content>
                    </paragraph>
                    <paragraph>Following parenteral infusion, the apparent steady state volume of distribution (V<sub>ss</sub>) of treprostinil is approximately 14 L/70 kg ideal body weight.</paragraph>
                    <paragraph>
                      <content styleCode="italics">In vitro</content> treprostinil is 91% bound to human plasma proteins over the 330 to 10,000 mcg/L concentration range.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
              <component>
                <section>
                  <id root="68fb1461-0628-4745-8161-e6ff3f41ae18"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="bold">Metabolism and Excretion</content>
                    </paragraph>
                    <paragraph>Of subcutaneously administered treprostinil, only 4% is excreted unchanged in urine. Treprostinil is substantially metabolized by the liver, primarily by CYP2C8. Metabolites are excreted in urine (79%) and feces (13%) over 10 days. Five apparently inactive metabolites were detected in the urine, each accounting for 10 to 15% of the dose administered. Four of the metabolites are products of oxidation of the 3-hydroxyloctyl side chain and 1 is a glucuroconjugated derivative (treprostinil glucuronide).</paragraph>
                    <paragraph>The elimination of treprostinil (following subcutaneous administration of treprostinil) is biphasic, with a terminal elimination half-life of approximately 4 hours using a 2-compartment model.</paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                </section>
              </component>
              <component>
                <section>
                  <id root="5371b1e9-4f53-4302-b002-7135e0279f51"/>
                  <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                  <text>
                    <paragraph>
                      <content styleCode="bold">Specific Populations</content>
                    </paragraph>
                  </text>
                  <effectiveTime value="20220506"/>
                  <component>
                    <section>
                      <id root="bbb7fcfd-83d3-44fd-9bc8-15a2db702c01"/>
                      <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                      <text>
                        <paragraph>
                          <content styleCode="italics">Hepatic Insufficiency</content>
                        </paragraph>
                        <paragraph>Plasma clearance of treprostinil, delivered subcutaneously, was reduced up to 80% in subjects presenting with mild-to-moderate hepatic insufficiency. Treprostinil has not been studied in patients with severe hepatic insufficiency <content styleCode="italics">[see <linkHtml href="#S8.6">Use in Specific Populations (8.6)</linkHtml>]</content>.</paragraph>
                      </text>
                      <effectiveTime value="20220506"/>
                    </section>
                  </component>
                  <component>
                    <section>
                      <id root="ac2e453d-7093-4121-8f7e-b4c4492da1d3"/>
                      <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
                      <text>
                        <paragraph>
                          <content styleCode="italics">Renal Impairment</content>
                        </paragraph>
                        <paragraph>In patients with severe renal impairment requiring dialysis (n=8), administration of a single 1 mg dose of orally administered treprostinil pre- and post-dialysis resulted in AUC<sub>0-inf</sub> that was not significantly altered compared to healthy subjects <content styleCode="italics">[see <linkHtml href="#S8.7">Use in Specific Populations (8.7)</linkHtml>]</content>.</paragraph>
                      </text>
                      <effectiveTime value="20220506"/>
                    </section>
                  </component>
                </section>
              </component>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S13">
          <id root="a9c7e84b-d464-4dd3-afe4-8631b2d3edf9"/>
          <code code="43680-8" codeSystem="2.16.840.1.113883.6.1" displayName="NONCLINICAL TOXICOLOGY SECTION"/>
          <title>13 NONCLINICAL TOXICOLOGY</title>
          <effectiveTime value="20220506"/>
          <component>
            <section ID="S13.1">
              <id root="a5800a29-0d5d-4618-81c9-ed21e59cb9ee"/>
              <code code="34083-6" codeSystem="2.16.840.1.113883.6.1" displayName="CARCINOGENESIS &amp; MUTAGENESIS &amp; IMPAIRMENT OF FERTILITY SECTION"/>
              <title>13.1 Carcinogenesis, Mutagenesis, Impairment of Fertility</title>
              <text>
                <paragraph>A 2-year rat carcinogenicity study was performed with treprostinil inhalation at target doses of 5.26, 10.6, and 34.1 mcg/kg/day. There was no evidence for carcinogenic potential associated with treprostinil inhalation in rats at systemic exposure levels up to 35 times the clinical exposure at the target maintenance dose of 54 mcg. <content styleCode="italics">In vitro</content> and <content styleCode="italics">in vivo</content> genetic toxicology studies did not demonstrate any mutagenic or clastogenic effects of treprostinil. Treprostinil sodium did not affect fertility or mating performance of male or female rats given continuous subcutaneous infusions at rates of up to 450 ng treprostinil/kg/min. In this study, males were dosed from 10 weeks prior to mating and through the 2-week mating period. Females were dosed from 2 weeks prior to mating until gestational day 6.</paragraph>
                <paragraph>Oral administration of treprostinil diolamine to Tg.rasH2 mice at 0, 5, 10, and 20 mg/kg/day in males and 0, 3, 7.5, and 15 mg/kg/day in females daily for 26 weeks did not significantly increase the incidence of tumors.</paragraph>
                <paragraph>Treprostinil diolamine was tested <content styleCode="italics">in vivo</content> in a rat micronucleus assay and did not induce an increased incidence of micronucleated polychromatic erythrocytes.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S13.2">
              <id root="dd9588b3-a43c-445d-a2e4-654b3c7268ff"/>
              <code code="34091-9" codeSystem="2.16.840.1.113883.6.1" displayName="ANIMAL PHARMACOLOGY &amp; OR TOXICOLOGY SECTION"/>
              <title>13.2 Animal Toxicology and/or Pharmacology</title>
              <text>
                <paragraph>In a 2-year rat study with treprostinil inhalation at target doses of 5.26, 10.6, and 34.1 mcg/kg/day, there were more deaths (11) in the mid- and high-dose treprostinil groups during the first 9 weeks of the study, compared to 1 in control groups. At the high-dose level, males showed a higher incidence of inflammation in teeth and preputial gland, and females showed higher incidences of inflammation and urothelial hyperplasia in the urinary bladder. The exposures in rats at mid- and high-dose levels were about 15 and 35 times, respectively, the clinical exposure at the target maintenance dose of 54 mcg.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S14">
          <id root="bb5d523e-03cb-4001-9750-2075672edbd9"/>
          <code code="34092-7" codeSystem="2.16.840.1.113883.6.1" displayName="CLINICAL STUDIES SECTION"/>
          <title>14 CLINICAL STUDIES</title>
          <effectiveTime value="20220506"/>
          <component>
            <section ID="S14.1">
              <id root="427e8d8a-83ac-4c62-a3ff-ffb8150aad91"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>14.1 Pulmonary Arterial Hypertension (WHO Group 1)</title>
              <text>
                <paragraph>TRIUMPH I, was a 12-week, randomized, double-blind, placebo-controlled, multicenter study of patients with PAH. The study population included 235 clinically stable subjects with PAH (WHO Group 1), nearly all with NYHA Class III (98%) symptoms who were receiving either bosentan (an endothelin receptor antagonist) or sildenafil (a phosphodiesterase-5 inhibitor) for at least 3 months prior to study initiation. Concomitant therapy also could have included anticoagulants, other vasodilators (e.g., calcium channel blockers), diuretics, oxygen, and digitalis, but not a prostacyclin. These patients were administered either placebo or Tyvaso in 4 daily treatment sessions with a target dose of 9 breaths (54 mcg) per session over the course of the 12-week study. Patients were predominately female (82%), had the origin of PAH as idiopathic/heritable (56%), secondary to connective tissue diseases (33%) or secondary to HIV or previous use of anorexigens (12%); bosentan was the concomitant oral medication in 70% of those enrolled, sildenafil in 30%.</paragraph>
                <paragraph>The primary efficacy endpoint of the trial was the change in 6-Minute Walk Distance (6MWD) relative to baseline at 12 weeks. 6MWD was measured at peak exposure (between 10 and 60 minutes after dosing), and 3 to 5 hours after bosentan or 0.5 to 2 hours after sildenafil. Patients receiving Tyvaso had a placebo-corrected median change from baseline in peak 6MWD of 20 meters at Week 12 (p&lt;0.001). The distribution of these 6MWD changes from baseline at Week 12 were plotted across the range of observed values (Figure 1). 6MWD measured at trough exposure (defined as measurement of 6MWD at least 4 hours after dosing) improved by 14 meters. There were no placebo-controlled 6MWD assessments made after 12 weeks. </paragraph>
                <paragraph ID="fig1">
                  <content styleCode="bold">Figure 1:	Distributions of 6MWD Changes from Baseline at Week 12 During Peak Plasma Concentration of Tyvaso</content>
                </paragraph>
                <paragraph>
                  <renderMultiMedia referencedObject="MM2"/>
                </paragraph>
                <paragraph>The placebo-corrected median treatment effect on 6MWD was estimated (using the Hodges-Lehmann estimator) within various subpopulations defined by age quartile, gender, geographic region of the study site, disease etiology, baseline 6MWD quartile, and type of background therapy (Figure 2).</paragraph>
                <paragraph ID="fig2">
                  <content styleCode="bold">Figure 2:	Placebo-Corrected Median Treatment Effect (Hodges-Lehmann Estimate with 95% CI) on 6MWD Change from Baseline at Week 12 During Peak Plasma Concentration of Tyvaso for Various Subgroups</content>
                </paragraph>
                <paragraph>
                  <renderMultiMedia referencedObject="MM3"/>
                </paragraph>
              </text>
              <effectiveTime value="20220506"/>
              <component>
                <observationMedia ID="MM2">
                  <text>Figure 1</text>
                  <value mediaType="image/jpeg" xsi:type="ED">
                    <reference value="tyvaso-02.jpg"/>
                  </value>
                </observationMedia>
              </component>
              <component>
                <observationMedia ID="MM3">
                  <text>Figure 2</text>
                  <value mediaType="image/jpeg" xsi:type="ED">
                    <reference value="tyvaso-03.jpg"/>
                  </value>
                </observationMedia>
              </component>
            </section>
          </component>
          <component>
            <section ID="S14.2">
              <id root="bada50e3-e16f-49d7-9183-076f1254ba9a"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>14.2 Long-term Treatment of PAH</title>
              <text>
                <paragraph>In long-term follow-up of patients who were treated with Tyvaso in the pivotal study and the open-label extension (N=206), Kaplan-Meier estimates of survival at 1, 2, and 3 years were 97%, 91%, and 82%, respectively. These uncontrolled observations do not allow comparison with a control group not given Tyvaso and cannot be used to determine the long-term effect of Tyvaso on mortality.</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
          <component>
            <section ID="S14.3">
              <id root="308c6b44-d982-4d10-bb8d-b09a39296962"/>
              <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
              <title>14.3 Pulmonary Hypertension Associated with ILD (WHO Group 3)</title>
              <text>
                <paragraph>INCREASE was a 16-week, randomized, double-blind, placebo-controlled, multicenter study that enrolled 326 patients with PH-ILD. Enrolled study patients predominately had etiologies of idiopathic interstitial pneumonia (45%) inclusive of idiopathic pulmonary fibrosis, combined pulmonary fibrosis and emphysema (25%), and WHO Group 3 connective tissue disease (22%). The mean baseline 6MWD was 260 meters.</paragraph>
                <paragraph>Patients in the INCREASE study were randomized (1:1) to either placebo or Tyvaso in 4 daily treatment sessions with a target dose of 9 breaths (54 mcg) per session and a maximum dose of 12 breaths (72 mcg) per session over the course of the 16-week study. Approximately 75% of patients randomized to Tyvaso titrated up to a dose of 9 breaths, 4 times daily or greater, with 48% of patients randomized to Tyvaso reaching a dose of 12 breaths, 4 times daily during the study.</paragraph>
                <paragraph>The primary efficacy endpoint was the change in 6MWD measured at peak exposure (between 10 and 60 minutes after dosing) from baseline to Week 16. Patients receiving Tyvaso had a placebo-corrected median change from baseline in peak 6MWD of 21 meters at Week 16 (p=0.004) using Hodges-Lehmann estimate (Figure 3).</paragraph>
                <paragraph ID="fig3">
                  <content styleCode="bold">Figure 3:	Hodges-Lehmann Estimate of Treatment Effect by Visit for 6MWD at Peak Exposure (PH-ILD)</content>
                </paragraph>
                <paragraph>
                  <renderMultiMedia referencedObject="MM3a"/>
                </paragraph>
                <paragraph>The treatment effect on 6MWD at Week 16 was consistent for various subgroups, including etiology of PH-ILD, disease severity, age, sex, baseline hemodynamics, and dose (Figure 4).</paragraph>
                <paragraph ID="fig4">
                  <content styleCode="bold">Figure 4:	Forest Plot on Subgroup Analyses of Peak 6MWD (Meter) at Week 16 (PH-ILD)</content>
                </paragraph>
                <paragraph>
                  <renderMultiMedia referencedObject="MM3b"/>
                </paragraph>
                <paragraph>Time to clinical worsening in the INCREASE study was defined as the time of randomization until 1 of the following criteria were met: hospitalization due to a cardiopulmonary indication, decrease in 6MWD &gt;15% from baseline directly related to PH-ILD at 2 consecutive visits and at least 24 hours apart, death (all causes), or lung transplantation. Treatment with Tyvaso in patients with PH-ILD resulted in numerically fewer hospitalizations. The numbers of reported deaths were the same for both treatment groups (Table 2). Overall, treatment with Tyvaso demonstrated a statistically significant increase in the time to first clinical worsening event (log-rank test p=0.041; Figure 5), and a 39% overall reduction in the risk of a clinical worsening event (HR=0.61 [95% CI; 0.40, 0.92]; Figure 5).</paragraph>
                <table ID="table2" width="80%">
                  <caption>Table 2:	Clinical Worsening Events (PH-ILD)</caption>
                  <col align="center" valign="top" width="12%"/>
                  <col align="left" valign="top" width="24%"/>
                  <col align="center" valign="top" width="21%"/>
                  <col align="center" valign="top" width="21%"/>
                  <col align="center" valign="top" width="22%"/>
                  <thead>
                    <tr>
                      <th colspan="2" styleCode="Lrule Rrule"/>
                      <th styleCode="Rrule">Tyvaso<br/>n=163<br/>n (%)</th>
                      <th styleCode="Rrule">Placebo <br/>n=163<br/>n (%)</th>
                      <th styleCode="Rrule">HR (95% CI)</th>
                    </tr>
                  </thead>
                  <tbody>
                    <tr styleCode="Botrule">
                      <td align="left" colspan="2" styleCode="Lrule Rrule">
                        <content styleCode="bold">Clinical worsening</content>
                      </td>
                      <td styleCode="Rrule">37 (22.7%)</td>
                      <td styleCode="Rrule">54 (33.1%)</td>
                      <td styleCode="Rrule">0.61 (0.40, 0.92)</td>
                    </tr>
                    <tr styleCode="Botrule">
                      <td rowspan="4" styleCode="Lrule Rrule" valign="middle">
                        <content styleCode="bold">First contributing event</content>
                      </td>
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Hospitalization due to a cardiopulmonary indication</content>
                      </td>
                      <td styleCode="Rrule">18 (11.0%)</td>
                      <td styleCode="Rrule">24 (14.7%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr styleCode="Botrule">
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Decrease in 6MWD &gt;15% from baseline directly related to PH-ILD</content>
                      </td>
                      <td align="center" styleCode="Rrule">13 (8.0%)</td>
                      <td styleCode="Rrule">26 (16.0%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr styleCode="Botrule">
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Death (all causes)</content>
                      </td>
                      <td align="center" styleCode="Rrule">4 (2.5%)</td>
                      <td styleCode="Rrule">4 (2.5%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr styleCode="Botrule">
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Lung transplantation</content>
                      </td>
                      <td align="center" styleCode="Rrule">2 (1.2%)</td>
                      <td styleCode="Rrule">0</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr styleCode="Botrule">
                      <td rowspan="4" styleCode="Lrule Rrule" valign="middle">
                        <content styleCode="bold">First of each event</content>
                      </td>
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Hospitalization due to a cardiopulmonary indication</content>
                      </td>
                      <td styleCode="Rrule">21 (12.9%)</td>
                      <td styleCode="Rrule">30 (18.4%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr styleCode="Botrule">
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Decrease in 6MWD &gt;15% from baseline directly related to PH-ILD</content>
                      </td>
                      <td align="center" styleCode="Rrule">16 (9.8%)</td>
                      <td styleCode="Rrule">31 (19.0%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr styleCode="Botrule">
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Death (all causes)</content>
                      </td>
                      <td align="center" styleCode="Rrule">8 (4.9%)</td>
                      <td styleCode="Rrule">10 (6.1%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                    <tr>
                      <td align="left" styleCode="Rrule">
                        <content styleCode="bold">Lung transplantation</content>
                      </td>
                      <td align="center" styleCode="Rrule">2 (1.2%)</td>
                      <td styleCode="Rrule">1 (0.6%)</td>
                      <td styleCode="Rrule"/>
                    </tr>
                  </tbody>
                </table>
                <paragraph ID="fig5">
                  <content styleCode="bold">Figure 5:	Kaplan-Meier Plot of Time to Clinical Worsening Events (PH-ILD)</content>
                </paragraph>
                <paragraph>
                  <renderMultiMedia referencedObject="MM3c"/>
                </paragraph>
              </text>
              <effectiveTime value="20220506"/>
              <component>
                <observationMedia ID="MM3a">
                  <text>Figure 3</text>
                  <value mediaType="image/jpeg" xsi:type="ED">
                    <reference value="tyvaso-03a.jpg"/>
                  </value>
                </observationMedia>
              </component>
              <component>
                <observationMedia ID="MM3b">
                  <text>Figure 4</text>
                  <value mediaType="image/jpeg" xsi:type="ED">
                    <reference value="tyvaso-03b.jpg"/>
                  </value>
                </observationMedia>
              </component>
              <component>
                <observationMedia ID="MM3c">
                  <text>Figure 5</text>
                  <value mediaType="image/jpeg" xsi:type="ED">
                    <reference value="tyvaso-03c.jpg"/>
                  </value>
                </observationMedia>
              </component>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S16">
          <id root="494cd45f-d8e7-4fc5-94d1-916e1f2180e5"/>
          <code code="34069-5" codeSystem="2.16.840.1.113883.6.1" displayName="HOW SUPPLIED SECTION"/>
          <title>16 HOW SUPPLIED/STORAGE AND HANDLING</title>
          <text>
            <paragraph>Tyvaso (treprostinil) inhalation solution is supplied in 2.9 mL clear LDPE ampules packaged as 4 ampules in a foil pouch. Tyvaso is a clear colorless to slightly yellow solution containing 1.74 mg treprostinil per ampule at a concentration of 0.6 mg/mL.</paragraph>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <section>
              <id root="2da1e916-04b9-4ff9-a288-494393f0e25b"/>
              <code code="44425-7" codeSystem="2.16.840.1.113883.6.1" displayName="STORAGE AND HANDLING SECTION"/>
              <text>
                <paragraph>Ampules of Tyvaso are stable until the date indicated when stored in the unopened foil pouch at 20-25°C (68-77°F) with excursions permitted to 15-30°C (59-86°F) [see USP Controlled Room Temperature]. Once the foil pack is opened, ampules should be used within 7 days. Because Tyvaso is light-sensitive, unopened ampules should be stored in the foil pouch.</paragraph>
                <paragraph>One ampule of Tyvaso should be used each day in the Tyvaso Inhalation System. After a Tyvaso ampule is opened and transferred to the medicine cup, the solution should remain in the device for no more than 1 day (24 hours). Any remaining solution should be discarded at the end of the day.</paragraph>
                <paragraph>Tyvaso Inhalation System Starter Kit containing a 28-ampule carton of Tyvaso (7 foil pouches each containing four 2.9 mL ampules; each ampule contains 1.74 mg treprostinil [0.6 mg per mL]) and the Tyvaso Inhalation System. (NDC 66302-206-01)</paragraph>
                <paragraph>Tyvaso Inhalation System Refill Kit containing a 28-ampule carton of Tyvaso (7 foil pouches each containing four 2.9 mL ampules; each ampule contains 1.74 mg treprostinil [0.6 mg per mL]) and accessories. (NDC 66302-206-02)</paragraph>
                <paragraph>Tyvaso 4 Pack Carton with 1 foil pouch containing four 2.9 mL ampules. Each ampule contains 1.74 mg treprostinil (0.6 mg per mL). (NDC 66302-206-03)</paragraph>
                <paragraph>Tyvaso Inhalation System Institutional Starter Kit containing a 4-ampule carton of Tyvaso (1 foil pouch containing four 2.9 mL ampules; each ampule contains 1.74 mg treprostinil [0.6 mg per mL]) and the Tyvaso Inhalation System. (NDC 66302-206-04)</paragraph>
              </text>
              <effectiveTime value="20220506"/>
            </section>
          </component>
        </section>
      </component>
      <component>
        <section ID="S17">
          <id root="cbb91697-1a6d-4921-8608-9f31d2ad7bc4"/>
          <code code="34076-0" codeSystem="2.16.840.1.113883.6.1" displayName="INFORMATION FOR PATIENTS SECTION"/>
          <title>17 PATIENT COUNSELING INFORMATION</title>
          <text>
            <paragraph>Advise the patient to read the FDA-approved patient labeling (Instructions for Use).</paragraph>
            <paragraph>Train patients in the administration process for Tyvaso, including dosing, Tyvaso Inhalation System set up, operation, cleaning, and maintenance, according to the instructions for use <content styleCode="italics">[see <linkHtml href="#S2.1">Dosage and Administration (2.1</linkHtml>, <linkHtml href="#S2.2">2.2)</linkHtml>]</content>.</paragraph>
            <paragraph>To avoid potential interruptions in drug delivery because of equipment malfunction, patients should have access to a back-up Tyvaso Inhalation System device <content styleCode="italics">[see <linkHtml href="#S2.2">Dosage and Administration (2.2)</linkHtml>]</content>.</paragraph>
            <paragraph>In the event that a scheduled treatment session is missed or interrupted, resume therapy as soon as possible <content styleCode="italics">[see <linkHtml href="#S2.1">Dosage and Administration (2.1)</linkHtml>]</content>.</paragraph>
            <paragraph>If Tyvaso comes in contact with the skin or eyes, instruct patients to rinse immediately with water <content styleCode="italics">[see <linkHtml href="#S2.2">Dosage and Administration (2.2)</linkHtml>]</content>.</paragraph>
          </text>
          <effectiveTime value="20220506"/>
        </section>
      </component>
      <component>
        <section>
          <id root="923f526f-df5d-4886-997e-b2a2a778b36c"/>
          <code code="42229-5" codeSystem="2.16.840.1.113883.6.1" displayName="SPL UNCLASSIFIED SECTION"/>
          <text>
            <paragraph>
              <sup>©</sup>Copyright 2022 United Therapeutics Corp. All rights reserved.</paragraph>
            <paragraph>Tyvaso manufactured for:</paragraph>
            <paragraph>United Therapeutics Corp.<br/>Research Triangle Park, NC 27709</paragraph>
          </text>
          <effectiveTime value="20220506"/>
        </section>
      </component>
      <component>
        <section ID="IFU_2">
          <id root="2ccb462d-cf31-4927-9feb-7c83da9f714d"/>
          <code code="59845-8" codeSystem="2.16.840.1.113883.6.1" displayName="INSTRUCTIONS FOR USE SECTION"/>
          <text>
            <paragraph>
              <content styleCode="bold italics">TYVASO</content>
              <sup>®</sup>
              <br/>
              <content styleCode="bold italics">INHALATION SYSTEM</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Instructions for Use Manual</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold italics">TYVASO</content>
              <sup>®</sup>
              <br/>
              <content styleCode="italics">(treprostinil)<br/>
                <content styleCode="bold">INHALATION<br/>SOLUTION</content>
              </content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Contents</content>
            </paragraph>
            <table ID="T1" styleCode="Noautorules" width="60%">
              <col align="left" valign="top" width="80%"/>
              <col align="right" valign="top" width="20%"/>
              <tbody>
                <tr>
                  <td>
                    <content styleCode="bold">Overview of your TYVASO Inhalation System</content>
                  </td>
                  <td>
                    <content styleCode="bold">4</content>
                  </td>
                </tr>
                <tr>
                  <td>  Introduction</td>
                  <td>6</td>
                </tr>
                <tr>
                  <td>  Safety and general instructions</td>
                  <td>8</td>
                </tr>
                <tr>
                  <td>  Buttons, indicators, and markings</td>
                  <td>10</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  Inhalation device display screens</td>
                  <td>16</td>
                </tr>
                <tr>
                  <td valign="bottom">
                    <content styleCode="bold">Programming your TYVASO Inhalation System before use</content>
                  </td>
                  <td valign="bottom">
                    <content styleCode="bold">18</content>
                  </td>
                </tr>
                <tr>
                  <td>  Charging device before use</td>
                  <td>20</td>
                </tr>
                <tr>
                  <td>  Setting your prescribed dose</td>
                  <td>22</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  Adjusting device's audio volume</td>
                  <td>24</td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Preparing and using your TYVASO Inhalation System for daily treatments</content>
                  </td>
                  <td>
                    <content styleCode="bold">26</content>
                  </td>
                </tr>
                <tr>
                  <td>  Prepare a proper environment</td>
                  <td>28</td>
                </tr>
                <tr>
                  <td>  Gather supplies</td>
                  <td>29</td>
                </tr>
                <tr>
                  <td>  Fill water chamber and medicine cup</td>
                  <td>32</td>
                </tr>
                <tr>
                  <td>  Assemble inhalation device</td>
                  <td>35</td>
                </tr>
                <tr>
                  <td>  Power on inhalation device</td>
                  <td>40</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  Inhale your medicine</td>
                  <td>42</td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Cleaning and Storing your TYVASO Inhalation System</content>
                  </td>
                  <td>
                    <content styleCode="bold">46</content>
                  </td>
                </tr>
                <tr>
                  <td>  Storing between sessions during the day</td>
                  <td>48</td>
                </tr>
                <tr>
                  <td>  End of day cleaning</td>
                  <td>52</td>
                </tr>
                <tr>
                  <td>  Recharging the battery</td>
                  <td>57</td>
                </tr>
                <tr>
                  <td>  Weekly cleaning</td>
                  <td>59</td>
                </tr>
                <tr>
                  <td>  Monthly Refill Kit</td>
                  <td>60</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  Replacing your devices</td>
                  <td>61</td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Help / More information about your TYVASO Inhalation System</content>
                  </td>
                  <td>
                    <content styleCode="bold">62</content>
                  </td>
                </tr>
                <tr>
                  <td>  Troubleshooting</td>
                  <td>64</td>
                </tr>
                <tr>
                  <td>  Specifications</td>
                  <td>76</td>
                </tr>
                <tr>
                  <td>  Electromagnetic compatibility (EMC)</td>
                  <td>79</td>
                </tr>
                <tr>
                  <td>  Glossary</td>
                  <td>87</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  Warranty information</td>
                  <td>90</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Overview of your TYVASO Inhalation System</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Section overview</content>
            </paragraph>
            <paragraph>This section introduces you to your TYVASO Inhalation System and provides important safety information about using your system.</paragraph>
            <table ID="T2" styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>What you will need:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  ▶ A clean place to review these instructions</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ TYVASO Inhalation System to refer to while reading instructions</td>
                </tr>
              </tbody>
            </table>
            <table ID="T3" styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="80%"/>
              <col align="right" valign="bottom" width="20%"/>
              <thead>
                <tr>
                  <th colspan="2">What is covered in this section:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  A: Introduction</td>
                  <td>6</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  B: Safety and general instructions</td>
                  <td>8</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  C: Buttons, indicators, and markings</td>
                  <td>10</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  D: Inhalation device display screens</td>
                  <td>16</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <paragraph>Do not start treatment with TYVASO until you have been trained to use the TYVASO Inhalation System. Make sure you understand all of the directions. Always ask your doctor or specialty pharmacy provider if you have any questions or are unsure of anything you are taught.</paragraph>
            <table ID="t4" styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">A: Introduction</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>Your doctor has prescribed TYVASO<sup>®</sup> (treprostinil) Inhalation Solution. Please see the accompanying Prescribing Information for important safety information on TYVASO.</paragraph>
            <paragraph>TYVASO is breathed in (inhaled) using the TYVASO Inhalation System, which consists of the inhalation device and its accessories.</paragraph>
            <paragraph>This Instructions for Use manual for the TYVASO Inhalation System provides important safety information. It is important that you read these instructions and the TYVASO Prescribing Information before setting up and using the TYVASO Inhalation System. If you have any questions, talk to your doctor or specialty pharmacy provider.</paragraph>
            <paragraph>Before beginning treatment with TYVASO, you will receive either a Patient Starter Kit containing a 28-day supply of TYVASO or an Institutional Starter Kit containing a 4-day supply of medication.</paragraph>
            <paragraph>Both kits include 2 complete inhalation devices (all accessories and supplies included). When you refill your prescription for TYVASO each month, you will receive a Refill Kit that contains a 28-day supply of TYVASO and new accessories. You will receive replacement devices every 2 years from your date of receipt of the TYVASO Inhalation System.</paragraph>
            <paragraph>
              <renderMultiMedia referencedObject="MM4"/> <content styleCode="bold">CAUTION: </content>Federal law restricts this device to sale by or on the order of a physician, or other licensed practitioner.</paragraph>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Keep this Instructions for Use manual in a safe place where you can easily get to it for reference. For example, store the booklet in the TYVASO Inhalation System carrying case, along with your other supplies.</item>
              <item>TYVASO Inhalation System is intended solely for the delivery of TYVASO (treprostinil) Inhalation Solution. TYVASO is for administration only with the TYVASO Inhalation System.</item>
            </list>
            <table ID="t5" styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">B: Safety and general instructions</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>The TYVASO Inhalation System should be handled carefully. Take the following precautions and follow all instructions in this document to avoid injury and ensure proper use:</paragraph>
            <paragraph>Delivering treatments:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Read the instructions carefully and completely to prevent damage to your TYVASO Inhalation System and help you get the best results.</item>
              <item>This device should only be used on the order of your doctor or licensed healthcare practitioner.</item>
              <item>Conduct only the number of treatment sessions and inhalations you have been prescribed.</item>
              <item>Ensure the breath counter is correctly programmed prior to beginning a treatment (see page 22).</item>
              <item>Turn off the device when not in use.</item>
              <item>Do not use the device with an anesthetic breathing system or ventilator breathing system.</item>
              <item>Use only the supplies provided in the Starter Kit and Monthly Refill Kit for correct device function.</item>
            </list>
            <paragraph>Handling the device:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Do not peel or remove the labels from the device.</item>
              <item>Do not drop the device.</item>
              <item>The device does not include internal, replaceable parts. Do not attempt to open the device, modify the device, or remove device labeling.</item>
            </list>
            <paragraph>Your environment:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Do not leave the device alone with a small child.</item>
              <item>Do not immerse the device in water or other liquids, or place in dishwasher.</item>
              <item>Do not place any system components in a microwave, conventional oven, or dishwasher.</item>
              <item>Do not use the device near flammable liquids and materials or heated surfaces.</item>
              <item>Do not place the device or use the device in the presence of strong electric or magnetic fields (e.g., microwave oven, magnetic imaging equipment).</item>
              <item>Wireless communications equipment (e.g., cell phone) can affect operation of the device and should be kept at least a distance of 3.3 meters (about 11 feet) away while using the device.</item>
              <item>If the device performance is affected by exposure to any conditions listed here, see the <linkHtml href="#Troubleshooting">Troubleshooting</linkHtml> section, or contact your healthcare provider or specialty pharmacy provider.</item>
            </list>
            <table ID="t6" styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">C: Buttons, indicators, and markings</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Inhalation device</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Inhalation indicator lights</content>
            </paragraph>
            <paragraph>Lights on top of device flash green when you should inhale.</paragraph>
            <paragraph>
              <content styleCode="bold">
                <renderMultiMedia referencedObject="MM5"/> On/Off, Start/Pause (blue) button</content>
            </paragraph>
            <paragraph>Press and <content styleCode="bold">hold</content> to power device on or off. Once device is on, press <content styleCode="bold">and immediately</content> release (do not hold down) to start or pause treatment.</paragraph>
            <paragraph>
              <content styleCode="bold">Device Display</content>
            </paragraph>
            <paragraph>Provides instructions and device information.</paragraph>
            <renderMultiMedia referencedObject="MM6"/>
            <paragraph>
              <content styleCode="bold">Run / Program switch</content>
            </paragraph>
            <paragraph>Slide up to Run mode when you are ready to deliver your dose. Slide down to Program mode to program the number of breaths for your dose.</paragraph>
            <paragraph>
              <content styleCode="bold">Volume / Breaths toggle button</content>
            </paragraph>
            <paragraph>When set to Run mode, push <content styleCode="bold">+</content> to increase beeping volume, or push <content styleCode="bold">-</content> to decrease beeping volume.</paragraph>
            <paragraph>When set to Program mode, push <content styleCode="bold">+</content> to increase the number of breaths, or push <content styleCode="bold">-</content> to decrease the number of breaths required for each dose.</paragraph>
            <renderMultiMedia referencedObject="MM7"/>
            <paragraph>
              <content styleCode="bold">Power status light</content>
            </paragraph>
            <paragraph>
              <renderMultiMedia referencedObject="MM8"/> Lights green when power is connected and battery is charging.</paragraph>
            <paragraph>
              <content styleCode="bold">Power port</content>
            </paragraph>
            <paragraph>Port for plugging into a power source using the AC wall plug.</paragraph>
            <renderMultiMedia referencedObject="MM9"/>
            <table styleCode="Noautorules" width="90%">
              <col align="center" valign="middle" width="20%"/>
              <col align="left" valign="middle" width="80%"/>
              <thead>
                <tr>
                  <th align="left" colspan="2">Additional device markings</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM10"/>
                  </td>
                  <td>Manufacturer. Indicates the medical device manufacturer.<br/>(Symbol 5.1.1 of ANSI/AAMI/ISO 15223-1: 2012 Medical devices - symbols to be used with medical devices labels, labeling, and information to be supplied - part 1: general requirements)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM11"/>
                  </td>
                  <td>Equipment should not be disposed of in the trash.<br/>(Figure 1 of BS EN 50419:2006 - Marking of Electrical and Electronic Equipment in accordance with Article 11(2) of Directive 2002/96/EC (WEEE))</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM12"/>
                  </td>
                  <td>Catalogue number. Indicates the manufacturer's catalogue number so that the medical device can be identified. (Symbol 5.1.6 of ANSI/AAMI/ISO 15223-1: 2012 Medical devices - symbols to be used with medical devices labels, labeling, and information to be supplied - part 1: general requirements)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM13"/>
                  </td>
                  <td>Serial number. Indicates the manufacturer's serial number so that a specific medical device can be identified. (Symbol 5.1.7 of ANSI/AAMI/ISO 15223-1: 2012 Medical devices - symbols to be used with medical devices labels, labeling, and information to be supplied - part 1: general requirements)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM14"/>
                  </td>
                  <td>Consult instructions for use. Please read the accompanying instructions and labels for important information regarding the TYVASO Inhalation System. (Symbol 5.4.3 of ANSI/AAMI/ISO 15223-1: 2012 Medical devices - symbols to be used with medical devices labels, labeling, and information to be supplied - part 1: general requirements)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM15"/>
                  </td>
                  <td>The TYVASO Inhalation System has a Type BF Applied part. Type BF Applied parts comply with specific requirements to provide protection against shock and are not suitable for direct cardiac applications.<br/>(Symbol 5333 of IEC 60417 Database Snapshot - Graphical symbols for use on equipment)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM16"/>
                  </td>
                  <td>The TYVASO Inhalation System requires a 14V DC power supply. Use only the power supply intended for the TYVASO Inhalation System.<br/> (Direct Current, Symbol 5031 of IEC 60417 Database Snapshot - Graphical symbols for use on equipment)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM17"/>
                  </td>
                  <td>The TYVASO Inhalation System complies with the requirements of Protection Class II. Class II equipment provides additional precautions, over and above basic insulation, to provide protection against electric shock. (Class II equipment, Symbol 5172 of IEC 60417 Database Snapshot - Graphical symbols for use on equipment)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM18"/>
                  </td>
                  <td>The TYVASO Inhalation Device provides level 2 solid particle protection and level 2 liquid ingress protection per IEC 60529 specifications.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM19"/>
                  </td>
                  <td>The TYVASO Inhalation System should only be used on the order of your doctor or licensed healthcare provider. (Symbol statement as provided under 21 CFR 801.109(b)(1))</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM20"/>
                  </td>
                  <td>Power stand by. Indicates the control for powering on and off the TYVASO Inhalation System. ("On" / "Off", Symbol 5010 of IEC 60417 Database Snapshot - Graphical symbols for use on equipment)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>
                    <renderMultiMedia referencedObject="MM21"/>
                  </td>
                  <td>Start/Pause. Indicates the control for starting a treatment session once the device is powered on, and for pausing a treatment once a treatment session has started. (Play and Pause, Symbols 5107B and 5111B, respectively, of IEC 60417 Database Snapshot - Graphical symbols for use on equipment)</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="100%">
              <col align="center" valign="top" width="25%"/>
              <col align="center" valign="top" width="25%"/>
              <col align="center" valign="top" width="25%"/>
              <col align="center" valign="top" width="25%"/>
              <thead>
                <tr styleCode="Botrule">
                  <th align="left" colspan="4">D: Inhalation device display screens</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM22"/>
                  </td>
                  <td styleCode="Lrule Rrule">
                    <renderMultiMedia referencedObject="MM23"/>
                  </td>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM24"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM25"/>
                  </td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Splash screen</content>
                    <br/>Device name and software version</td>
                  <td styleCode="Lrule Rrule">
                    <content styleCode="bold">Last Treatment</content>
                    <br/>Time since your last treatment</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Program Breaths</content>
                    <br/>Number of breaths set in Program mode</td>
                  <td>
                    <content styleCode="bold">Adjust Volume</content>
                    <br/>Audio volume level set in Run mode</td>
                </tr>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM26"/>
                  </td>
                  <td styleCode="Lrule Rrule">
                    <renderMultiMedia referencedObject="MM27"/>
                  </td>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM28"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM29"/>
                  </td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Breaths Left</content>
                    <br/>Number of breaths left in a current dose</td>
                  <td styleCode="Lrule Rrule">
                    <content styleCode="bold">Exhale</content>
                    <br/>Prompt to exhale during a dose</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Inhale</content>
                    <br/>Prompt to inhale during a dose</td>
                  <td>
                    <content styleCode="bold">Done</content>
                    <br/>Treatment session is complete</td>
                </tr>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM30"/>
                  </td>
                  <td styleCode="Lrule Rrule">
                    <renderMultiMedia referencedObject="MM31"/>
                  </td>
                  <td align="left" colspan="2" rowspan="3">
                    <renderMultiMedia referencedObject="MM32"/>
                  </td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Pause</content>
                    <br/>You have paused a treatment session</td>
                  <td styleCode="Lrule Rrule">
                    <content styleCode="bold">Call Support</content>
                    <br/>Device is not working, call your specialty pharmacy provider for support</td>
                </tr>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM33"/>
                  </td>
                  <td styleCode="Lrule Rrule">
                    <renderMultiMedia referencedObject="MM34"/>
                  </td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Add Water</content>
                    <br/>Wrong or missing fluid in water chamber</td>
                  <td styleCode="Lrule Rrule">
                    <content styleCode="bold">Charge Battery</content>
                    <br/>Battery not charged enough to deliver treatment</td>
                  <td>
                    <content styleCode="bold">Status icons</content>
                    <br/>Icons that might appear at bottom of the screen</td>
                  <td/>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Programming your TYVASO Inhalation System before use</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Section overview</content>
            </paragraph>
            <paragraph>This section provides instructions for charging your device, setting your dose, and adjusting the device's audio volume before you use the device for a treatment.</paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>What you will need:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  ▶ A clean place to work with the device</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ TYVASO Inhalation Device</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ The number of breaths your doctor prescribed for each dose</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="80%"/>
              <col align="right" valign="bottom" width="20%"/>
              <thead>
                <tr>
                  <th colspan="2">What is covered in this section:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  A: Charging device before use</td>
                  <td>20</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  B: Setting your prescribed dose</td>
                  <td>22</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  C: Adjusting device's audio volume</td>
                  <td>24</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <paragraph>Do not start treatment with TYVASO until you have been trained to use the TYVASO Inhalation System. Make sure you understand all of the directions. Always ask your doctor or specialty pharmacy provider if you have any questions or are unsure of anything you are taught.</paragraph>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">A: Charging device before use</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">1. Plug in device</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Important:</content> A new device might not be fully charged when you receive it. Always charge the device before you first use it. You can also charge the device overnight, when not in use and in between uses.</paragraph>
            <paragraph>Plug the AC wall plug's white connector into the port on the back of the inhalation device. Then, plug the AC wall plug into the wall outlet.</paragraph>
            <paragraph>The power status light above the port will light green when properly plugged in.</paragraph>
            <renderMultiMedia referencedObject="MM35"/>
            <paragraph>
              <content styleCode="bold">2. Check the battery's status</content>
            </paragraph>
            <paragraph>Make sure the Run / Program switch is set to Run. Press and <content styleCode="bold">hold</content> the blue button to power on the device.</paragraph>
            <paragraph>The battery icon at the bottom of the screen indicates battery status.</paragraph>
            <paragraph>When you are done checking the battery status, press and <content styleCode="bold">hold</content> the On/Off button until the display screen shuts off (note: letting the button go before the screen shuts off will start a treatment session).</paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="top" width="50%"/>
              <col align="center" valign="middle" width="50%"/>
              <tbody>
                <tr>
                  <td>If there is not enough charge to conduct a treatment session, "Charge battery" appears on screen.</td>
                  <td>
                    <renderMultiMedia referencedObject="MM34"/>
                  </td>
                </tr>
              </tbody>
            </table>
            <renderMultiMedia referencedObject="MM36"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">B: Setting your prescribed dose</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>Your doctor will prescribe the number of breaths you should take in each treatment session. You should program this number into the inhalation device before you use the device.</paragraph>
            <paragraph>
              <content styleCode="bold">1. Switch to Program</content>
            </paragraph>
            <paragraph>Slide the Run / Program switch on the side of the device down to Program mode. In Program mode you enter the prescribed number of breaths for each dose. You cannot begin a treatment in Program mode.</paragraph>
            <renderMultiMedia referencedObject="MM37"/>
            <paragraph>
              <content styleCode="bold">2. Power on</content>
            </paragraph>
            <paragraph>Press and <content styleCode="bold">hold</content> the On/Off button until the display screen turns on. The Program Breaths screen appears. The number of breaths currently set for each treatment session will flash.</paragraph>
            <renderMultiMedia referencedObject="MM38"/>
            <paragraph>
              <content styleCode="bold">3. Set breaths</content>
            </paragraph>
            <paragraph>Use the Volume / Breaths toggle button to enter your prescribed number of breaths onto the program screen.</paragraph>
            <renderMultiMedia referencedObject="MM39"/>
            <paragraph>
              <content styleCode="bold">4. Switch to Run</content>
            </paragraph>
            <paragraph>Slide the Run / Program switch up to Run mode. Make sure your new breath count appears on screen.</paragraph>
            <renderMultiMedia referencedObject="MM40"/>
            <paragraph>
              <content styleCode="bold">5. Power off</content>
            </paragraph>
            <paragraph>Press and <content styleCode="bold">hold</content> the On/Off button until the display screen shuts off (note: letting the button go before the screen shuts off will start a treatment session).</paragraph>
            <paragraph>Note: You will not need to program the breath count again, unless your prescribed number of breaths changes.</paragraph>
            <renderMultiMedia referencedObject="MM41"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">C: Adjusting device's audio volume</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>You can use the Volume / Breaths toggle button to adjust the volume of the audible signals (beeps) that the device provides as feedback during treatment sessions.</paragraph>
            <paragraph>
              <content styleCode="bold">1. Switch to Run</content>
            </paragraph>
            <paragraph>Slide the Run / Program switch up to Run mode, if it is not in this position already.</paragraph>
            <renderMultiMedia referencedObject="MM42"/>
            <paragraph>
              <content styleCode="bold">2. Power on</content>
            </paragraph>
            <paragraph>Press and <content styleCode="bold">hold</content> the On/Off button until the display screen turns on, if it is not already turned on. The programmed number of breaths will appear with the words "Breaths left" and the battery icon at the bottom.</paragraph>
            <renderMultiMedia referencedObject="MM43"/>
            <paragraph>
              <content styleCode="bold">3. Adjust volume</content>
            </paragraph>
            <paragraph>With the Run / Program switch in the Run position, press the Volume / Breaths toggle button to access the Adjust Volume screen. Push + on the Volume / Breaths toggle button to increase beeping volume, or push - to decrease beeping volume.</paragraph>
            <table styleCode="Noautorules" width="85%">
              <col align="center" valign="middle" width="33%"/>
              <col align="center" valign="middle" width="33%"/>
              <col align="center" valign="middle" width="34%"/>
              <tbody>
                <tr>
                  <td colspan="3">
                    <renderMultiMedia referencedObject="MM44"/>
                  </td>
                </tr>
                <tr>
                  <td align="right">
                    <paragraph>
                      <renderMultiMedia referencedObject="MM45"/>
                    </paragraph>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM46"/>
                  </td>
                  <td align="left">
                    <paragraph>
                      <renderMultiMedia referencedObject="MM47"/>
                    </paragraph>
                  </td>
                </tr>
                <tr>
                  <td align="right">audio off      </td>
                  <td align="center">mid-level volume</td>
                  <td align="left">maximum volume</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">4. Power off</content>
            </paragraph>
            <paragraph>After adjusting the beeping volume up or down, the screen will display your new setting for a couple of seconds then return to the screen displaying the breaths left.</paragraph>
            <paragraph>Press and <content styleCode="bold">hold</content> the On/Off button until the display screen shuts off (note: letting the button go before the screen shuts off will start a treatment session).</paragraph>
            <renderMultiMedia referencedObject="MM48"/>
            <paragraph styleCode="bold">Preparing and using your TYVASO Inhalation System for daily treatments</paragraph>
            <paragraph styleCode="bold">Section overview</paragraph>
            <paragraph>This section provides instructions for preparing and using your TYVASO Inhalation System for daily treatments.</paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>What you will need:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>▶ A clean place to take your medicine</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ TYVASO Inhalation device</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ TYVASO Inhalation supplies</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">▶ One ampule of TYVASO Inhalation Solution</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="80%"/>
              <col align="right" valign="bottom" width="20%"/>
              <thead>
                <tr>
                  <th colspan="2">What is covered in this section:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  A: Prepare a proper environment</td>
                  <td>28</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  B: Gather supplies</td>
                  <td>29</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  C: Fill water chamber and medicine cup</td>
                  <td>32</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  D: Assemble inhalation device</td>
                  <td>35</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  E: Power on inhalation device</td>
                  <td>40</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  F: Inhale your medicine</td>
                  <td>42</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <paragraph>Before using the TYVASO Inhalation System, you should:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Wash your hands.</item>
              <item>Make sure the device is resting on a stable, flat surface during assembly.<br/>
                <renderMultiMedia referencedObject="MM49"/>
              </item>
            </list>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">A: Prepare a proper environment</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>Follow these important instructions before setting up your treatment:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Use the device in a quiet, distraction-free area.</item>
              <item>Try to use the device at times when your treatment will not be interrupted. If needed, you can pause your treatment (see page 44).</item>
              <item>Use the device in a comfortable space where you can stand or sit in an upright position.</item>
              <item>Use the device in an area where you can access a power source if you need to use the AC wall plug.</item>
              <item>The TYVASO Inhalation System is recommended for use indoors.</item>
              <item>Use the device in an area that provides enough space for the TYVASO Inhalation System and its accessories.</item>
              <item>Gather all necessary supplies on a stable, flat surface for assembly (see page 29 for list of supplies).</item>
              <item>Store the inhalation device at 15°C to 30°C (59°F to 86°F). Use at 15°C to 25°C (59°F to 77°F).</item>
              <item>Use the device in a well-lit area where you can clearly read these instructions, labels on the device, and the device screen.</item>
            </list>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">B: Gather supplies</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>Gather the following supplies before starting treatment. Use only the supplies provided in the starter kit and monthly refill kit for correct device function. Prior to use, inspect each part and do not use parts if they appear damaged or dirty.</paragraph>
            <table styleCode="Noautorules" width="90%">
              <col align="center" valign="top" width="33%"/>
              <col align="center" valign="top" width="33%"/>
              <col align="center" valign="top" width="34%"/>
              <tbody>
                <tr>
                  <td colspan="2">
                    <renderMultiMedia referencedObject="MM50"/>
                  </td>
                  <td align="center" valign="middle">
                    <renderMultiMedia referencedObject="MM51"/>
                  </td>
                </tr>
                <tr>
                  <td>
                    <content styleCode="bold">Inhalation device</content>
                    <br/>Powered off</td>
                  <td>
                    <content styleCode="bold">TYVASO ampules</content>
                    <br/>Use 1 ampule per day</td>
                  <td>
                    <content styleCode="bold">Water level cup</content>
                    <br/>with 45 mL of distilled water</td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM52"/>
                  </td>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM53"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM54"/>
                  </td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Filter membranes<footnote ID="footb1">These accessories are replaced every month. Replacement accessories are included in the Monthly Refill Kit.</footnote>
                    </content>
                    <br/>Use 2 per day</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Medicine cups<footnoteRef IDREF="footb1"/>
                    </content>
                    <br/>Use 1 per day</td>
                  <td>
                    <content styleCode="bold">Dome assembly<footnoteRef IDREF="footb1"/>
                    </content>
                  </td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM55"/>
                  </td>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM56"/>
                  </td>
                  <td valign="bottom">
                    <renderMultiMedia referencedObject="MM57"/>
                  </td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Mouthpiece<footnoteRef IDREF="footb1"/>
                    </content>
                  </td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Inhalation piece<footnoteRef IDREF="footb1"/>
                    </content>
                  </td>
                  <td>
                    <content styleCode="bold">2 filter shells<footnoteRef IDREF="footb1"/>
                    </content>
                  </td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM58"/>
                  </td>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM59"/>
                  </td>
                  <td valign="bottom">
                    <renderMultiMedia referencedObject="MM60"/>
                  </td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <content styleCode="bold">2 Plugs<footnoteRef IDREF="footb1"/>
                    </content>
                    <br/>(Used when storing the device)</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Carrying case</content>
                  </td>
                  <td>
                    <content styleCode="bold">Pen or pencil</content> (not provided) to record your treatment</td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM61"/>
                  </td>
                  <td styleCode="Rrule">
                    <renderMultiMedia referencedObject="MM62"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM63"/>
                  </td>
                </tr>
                <tr>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Distilled water carrier</content>
                  </td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">AC wall plug</content>
                  </td>
                  <td>
                    <content styleCode="bold">Treatment Tracker Example</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">C: Fill water chamber and medicine cup</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <list listType="unordered" styleCode="disc">
              <item>
                <content styleCode="bold">Wash your hands</content>
                <br/>
                <renderMultiMedia referencedObject="MM49"/>
              </item>
              <item>
                <content styleCode="bold">Unplug device </content>when filling to avoid damage to cords or connectors.</item>
              <item>
                <content styleCode="bold">Only use distilled water</content> in the device. Distilled water is highly purified water that is required for the device to function properly. If you use another type of water (such as bottled or tap water), the device might not function properly. You can purchase distilled water at most grocery stores and pharmacies.</item>
            </list>
            <paragraph>
              <content styleCode="bold">1. Fill water chamber</content>
            </paragraph>
            <paragraph>Fill the water level cup with distilled water up to the arrow markers on the water cup. Use fresh distilled water each day (i.e., do not use water left in the water chamber from the previous day). Pour the distilled water into the water chamber.</paragraph>
            <paragraph>Make sure the water level is above the upper, silver sensor and below the blue ring in the water chamber (about 45 mL of distilled water).</paragraph>
            <paragraph>Do not overfill the water chamber, or else the medicine cup might not fit correctly.</paragraph>
            <renderMultiMedia referencedObject="MM64"/>
            <paragraph>
              <content styleCode="bold">2. Place medicine cup</content>
            </paragraph>
            <paragraph>Obtain 1 new medicine cup and inspect it. <content styleCode="bold">Do not</content> use a medicine cup that is damaged (e.g., cracked or contains holes or dents), dirty, or was used before.</paragraph>
            <paragraph>Place the empty medicine cup into the water chamber of the device, making sure that the cup's bottom tip is in the distilled water.</paragraph>
            <renderMultiMedia referencedObject="MM65"/>
            <paragraph>
              <renderMultiMedia referencedObject="MM4"/> <content styleCode="bold">CAUTION:</content> Make sure you place only 1 medicine cup. Placing multiple cups will prevent the flow of medicine.</paragraph>
            <paragraph>
              <content styleCode="bold">3. Gather one ampule</content>
            </paragraph>
            <paragraph>Carefully cut open the top of the foil pouch, making sure not to cut the ampules. Each pouch contains 4 ampules. Remove 1 ampule of TYVASO.</paragraph>
            <paragraph>Keep unused ampules in the foil pouch because the TYVASO medicine is sensitive to light. Write the date you first opened the pouch on the foil pouch.</paragraph>
            <paragraph>One ampule contains enough medicine for 1 day of treatment no matter how many breaths your doctor has prescribed.</paragraph>
            <renderMultiMedia referencedObject="MM66"/>
            <paragraph>
              <renderMultiMedia referencedObject="MM4"/> <content styleCode="bold">CAUTION: </content>Ampules must be used within 7 days of opening foil pouch. Open only 1 pouch at a time. Throw away (discard) any unused ampules after 7 days.</paragraph>
            <paragraph>
              <content styleCode="bold">4. Open ampule</content>
            </paragraph>
            <paragraph>Gently hold the ampule in the upright (top up) position and twist off its top.</paragraph>
            <renderMultiMedia referencedObject="MM67"/>
            <paragraph>
              <renderMultiMedia referencedObject="MM4"/> <content styleCode="bold">CAUTION:</content> If any medicine from the ampule spills on your hands, wash your hands right away. Medicine contact with the skin can cause irritation.</paragraph>
            <paragraph>
              <content styleCode="bold">5. Squeeze ampule</content>
            </paragraph>
            <paragraph>Point the ampule straight down toward the medicine cup's center to avoid spills.</paragraph>
            <paragraph>Gently squeeze the medicine out of the ampule into the medicine cup. Squeeze until it is empty. Check to see that all of the medicine is in the medicine cup.</paragraph>
            <renderMultiMedia referencedObject="MM68"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">D: Assemble inhalation device</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content> Do not force parts together.</paragraph>
            <paragraph>The TYVASO Inhalation System is designed so the parts only fit together properly one way. When the device is assembled correctly, the parts should fit together easily.</paragraph>
            <renderMultiMedia referencedObject="MM69"/>
            <paragraph>
              <content styleCode="bold">1. Check dome assembly</content>
            </paragraph>
            <paragraph>Visually check to make sure the black ring is securely placed in the dome assembly. The black ring should look like it does in the pictures below.</paragraph>
            <paragraph>If the black ring is loose or missing, do not use the dome assembly. Throw it away and get a new one. If you need to order a new dome assembly, contact your specialty pharmacy provider.</paragraph>
            <renderMultiMedia referencedObject="MM70"/>
            <paragraph>
              <content styleCode="bold">2. Attach dome assembly</content>
            </paragraph>
            <paragraph>Align the raised circle on the side of the dome assembly with the raised circle on the side of the device.</paragraph>
            <paragraph>Push down and screw the dome assembly onto the device clockwise (right) until the filter shell port is tight and pointed to the back of the device. You will hear clicks (or a slight crunching sound) as the dome assembly presses down on the medicine cup.</paragraph>
            <paragraph>
              <content styleCode="bold">Important:</content> The dome assembly "clicks" only the first time it connects to the medicine cup. If you then realign the dome assembly you will not hear another click.</paragraph>
            <renderMultiMedia referencedObject="MM71"/>
            <paragraph>
              <content styleCode="bold">3. Install new filter membrane</content>
            </paragraph>
            <paragraph>Each day you will need to use a new filter membrane in each filter shell.</paragraph>
            <paragraph>Note: New filter shells come with fresh filter membranes already installed.</paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr>
                  <td>To install a new filter membrane:</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ a. Open the filter shell by unscrewing the 2 halves.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ b. Place a new filter membrane in 1 of the filter shell halves.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ c. Close the filter shell by screwing the 2 halves together until you can twist no further.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ d. Repeat steps a-c for second filter shell.</td>
                </tr>
              </tbody>
            </table>
            <renderMultiMedia referencedObject="MM72"/>
            <paragraph>
              <content styleCode="bold">4. Attach filter shells</content>
            </paragraph>
            <paragraph>Insert 1 filter shell into the filter shell port on the side of the dome assembly and insert the second filter shell into the port on the bottom of the inhalation piece. The filter shells are the same and can be used in either port. You can turn the filter shells around to fit into the ports, as needed.</paragraph>
            <paragraph>Make sure to insert filter shells straight into ports, not at an angle.</paragraph>
            <renderMultiMedia referencedObject="MM73"/>
            <paragraph>
              <content styleCode="bold">5. Insert inhalation piece</content>
            </paragraph>
            <paragraph>Insert the inhalation piece with attached filter shell into the upper opening of the dome assembly and turn it toward the front of the device. Gently push down the inhalation piece to make sure it is securely inserted in the dome assembly.</paragraph>
            <renderMultiMedia referencedObject="MM74"/>
            <paragraph>
              <content styleCode="bold">6. Insert mouthpiece</content>
            </paragraph>
            <paragraph>Carefully insert the mouthpiece into the inhalation piece.</paragraph>
            <renderMultiMedia referencedObject="MM75"/>
            <paragraph>
              <content styleCode="bold">7. Check assembled device</content>
            </paragraph>
            <paragraph>When the device is fully assembled, it should look like it does below. Slightly turn the inhalation piece so you can see the display screen, which provides important prompts during your treatment.</paragraph>
            <renderMultiMedia referencedObject="MM76"/>
            <paragraph>
              <content styleCode="bold">Important: Do not</content> use device if you see liquid leaking from bottom of the device.</paragraph>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">E: Power on inhalation device</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">1. Power on device</content>
            </paragraph>
            <paragraph>Press and <content styleCode="bold">hold</content> the On/Off button until the screen turns on and the device beeps once.</paragraph>
            <paragraph>The screen will display the splash screen, then the time since your last treatment, then the current breaths programmed for each dose.</paragraph>
            <renderMultiMedia referencedObject="MM77"/>
            <paragraph>
              <content styleCode="bold">Important: </content>Make sure the number on screen above "Breaths left" matches the prescribed number of breaths for that treatment session. If it does not match, see page 22 for instructions on setting the number of breaths for a treatment session.</paragraph>
            <renderMultiMedia referencedObject="MM78"/>
            <paragraph>
              <content styleCode="bold">2. Plug in device, if needed</content>
            </paragraph>
            <paragraph>If the device's internal battery is too low to deliver a full treatment, the screen will display an instruction to plug in the power to charge the device battery. If the battery is fully depleted, the screen will not turn on.</paragraph>
            <renderMultiMedia referencedObject="MM34"/>
            <paragraph>You can charge the battery at any time, before the screen displays "Charge battery."</paragraph>
            <paragraph>You can conduct a treatment session with the power plugged in. First, plug the AC wall plug's white connector into the port on the back of the inhalation device. Then, plug the AC wall plug into the wall outlet. The power status light above the port will light green when properly plugged in.</paragraph>
            <renderMultiMedia referencedObject="MM79"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">F: Inhale your medicine</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">1. Before starting, confirm treatment</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">You will breathe in (inhale) TYVASO during 4 treatment sessions each day (evenly spaced during your waking hours). During each treatment session, you will take a series of breaths through the mouthpiece of the TYVASO Inhalation System.</content>
            </paragraph>
            <paragraph>Before inhaling your medicine, ensure the Run/Program switch is in the 'Run' position, and make sure the number displayed on screen matches your prescribed number of breaths for that treatment session. During the treatment the device counts down each breath after a set time interval. Once you complete all breaths, record the breath number in your Treatment Tracker.</paragraph>
            <paragraph>
              <content styleCode="bold">Important:</content> If the number of breaths displayed does not match the number of breaths in your prescription, see page 22 "Setting your prescribed dose" and repeat steps 1-4.</paragraph>
            <renderMultiMedia referencedObject="MM80"/>
            <paragraph>
              <content styleCode="bold">2. Hold the device upright</content>
            </paragraph>
            <paragraph>Hold the device upright and stand or sit in an upright position as shown below. Avoid covering the bottom of the device so that the audio speaker is not blocked.</paragraph>
            <paragraph>Make sure you can see the display screen and lights clearly and that your hands do not cover the display screen or lights while holding device. If needed, you can move the inhalation piece and mouthpiece slightly to either side to see the screen and lights better.</paragraph>
            <renderMultiMedia referencedObject="MM81"/>
            <paragraph>See next page to start treatment.</paragraph>
            <paragraph>
              <content styleCode="bold">Inhalation tips:</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Technique:</content>
            </paragraph>
            <paragraph>When breathing each TYVASO treatment, be sure to keep the device level, directing the flow of medicine into the throat and not toward the roof of the mouth.</paragraph>
            <paragraph>Seal your lips around the mouthpiece to ensure that you can inhale the full amount of TYVASO after it is produced by the device.</paragraph>
            <paragraph>
              <content styleCode="bold">Inhalation:</content>
            </paragraph>
            <paragraph>Each breath should last approximately 3 seconds, breathing "normal full breaths." Do not hold your breath. Remove your lips from the mouthpiece, breathe out (exhale) normally and prepare for the next breath.</paragraph>
            <paragraph>
              <content styleCode="bold">3. Press blue button to start treatment</content>
            </paragraph>
            <paragraph>If you need to pause treatment, you can press <content styleCode="bold">and immediately</content> release (do not hold down) the blue button. Press the button again <content styleCode="bold">and immediately</content> release to resume treatment. (Note: If you do not resume treatment after pausing, power off device.)</paragraph>
            <renderMultiMedia referencedObject="MM82"/>
            <paragraph>
              <content styleCode="bold">4. Wait</content>
            </paragraph>
            <paragraph>Look at the display screen for cues. Wait until you hear 2 short beeps. When you hear 1 long beep, exhale to prepare to inhale.</paragraph>
            <renderMultiMedia referencedObject="MM83"/>
            <paragraph>
              <content styleCode="bold">5. Inhale</content>
            </paragraph>
            <paragraph>When you hear 1 short beep and the indicator lights flash green, place your lips securely around the mouthpiece and inhale for 3 seconds. When lights stop flashing, remove lips from mouthpiece and exhale normally.</paragraph>
            <renderMultiMedia referencedObject="MM84"/>
            <paragraph>
              <content styleCode="bold">6. Repeat for each breath left</content>
            </paragraph>
            <paragraph>The screen will decrease the number of breaths left by 1. Repeat steps 4 and 5 for the number of prescribed breaths.</paragraph>
            <renderMultiMedia referencedObject="MM85"/>
            <paragraph>
              <content styleCode="bold">7. Finish session</content>
            </paragraph>
            <paragraph>After displaying the last breath sequence, the green Done screen appears, you will hear a beep, and your treatment is done.</paragraph>
            <renderMultiMedia referencedObject="MM86"/>
            <paragraph>If the device is left in the "✓ Done" mode for more than 60 seconds, it will turn off automatically.</paragraph>
            <paragraph>
              <content styleCode="bold">8. Record breaths, turn off device</content>
            </paragraph>
            <paragraph>Record the number of breaths you inhaled on the Treatment Tracker.</paragraph>
            <renderMultiMedia referencedObject="MM87"/>
            <paragraph>Press and <content styleCode="bold">hold</content> blue button until screen turns off.</paragraph>
            <renderMultiMedia referencedObject="MM88"/>
            <paragraph>
              <renderMultiMedia referencedObject="MM4"/> <content styleCode="bold">CAUTION:</content> If medicine does not appear to be flowing properly, the system might be set up incorrectly. See "<linkHtml href="#Troubleshooting">Troubleshooting</linkHtml>", starting on page 64 for details.</paragraph>
            <paragraph>
              <content styleCode="bold">Cleaning and Storing your TYVASO Inhalation System</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Section overview</content>
            </paragraph>
            <paragraph>This section provides instructions for storing your TYVASO Inhalation System after each treatment and daily and weekly cleaning.</paragraph>
            <paragraph>There is also information about your monthly refill kits, replacing your device, and recharging the device's battery.</paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>What you will need:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  ▶ A clean place to work with the device</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ TYVASO Inhalation device</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ TYVASO Inhalation supplies</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="80%"/>
              <col align="right" valign="bottom" width="20%"/>
              <thead>
                <tr>
                  <th colspan="2">What is covered in this section:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  A: Storing between sessions during the day</td>
                  <td>48</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  B: End of day cleaning</td>
                  <td>52</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  C: Recharging the battery</td>
                  <td>57</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  D: Weekly cleaning</td>
                  <td>59</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  E: Monthly Refill Kit</td>
                  <td>60</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  F: Replacing your devices</td>
                  <td>61</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <paragraph>For further support, you can:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Fill out and refer to your emergency contact information on the back of this Instructions for Use manual.</item>
              <item>Call 1-844-UNITHER (1-844-864-8437) for questions and information, or to report an adverse reaction.</item>
            </list>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">A: Storing between sessions during the day</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">If you have more treatment sessions left in the day, perform the steps in this section.</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">If you have completed your last treatment session of the day, skip to "End of day cleaning" on page 52.</content>
            </paragraph>
            <paragraph>Be sure to pack all parts, including the AC wall plug, in the carrying case whenever transporting your device.</paragraph>
            <paragraph>
              <content styleCode="bold">1. Disconnect AC wall plug</content>
              <br/>(if it is currently connected)</paragraph>
            <renderMultiMedia referencedObject="MM89"/>
            <paragraph>
              <content styleCode="bold">2. Remove mouthpiece</content>
            </paragraph>
            <renderMultiMedia referencedObject="MM90"/>
            <paragraph>
              <content styleCode="bold">3. Remove inhalation piece</content>
            </paragraph>
            <renderMultiMedia referencedObject="MM91"/>
            <paragraph>
              <content styleCode="bold">Important:</content> When removing accessories between treatment sessions, hold the device by its base to avoid spilling the medicine.</paragraph>
            <paragraph>
              <content styleCode="bold">4. Remove both filter shells</content>
            </paragraph>
            <paragraph>Note: <content styleCode="bold">Do not</content> remove the filter membranes from filter shells until after the last treatment session of the day.</paragraph>
            <renderMultiMedia referencedObject="MM92"/>
            <paragraph>
              <content styleCode="bold">5. Leave dome assembly</content>
            </paragraph>
            <paragraph>Leave dome assembly and medicine cup (with the medicine still in it) attached to the device.</paragraph>
            <renderMultiMedia referencedObject="MM93"/>
            <paragraph>
              <content styleCode="bold">6. Place plugs in dome assembly</content>
            </paragraph>
            <paragraph>Insert a plug into each of the 2 open holes on the dome assembly to prevent the medicine from spilling out.</paragraph>
            <renderMultiMedia referencedObject="MM94"/>
            <paragraph>
              <content styleCode="bold">Important:</content> If the plugs are not in place, the medicine may spill. If you spill any medicine, discard remaining medicine and start your next treatment with a new ampule.</paragraph>
            <paragraph>
              <content styleCode="bold">7. Store in carrying case</content>
            </paragraph>
            <paragraph>You can store the inhalation device with the plugged dome assembly and disassembled accessories in the carrying case between treatment sessions.</paragraph>
            <paragraph>Keep the carrying case upright while inserting the device and components so that water and medicine does not spill out of the device.</paragraph>
            <renderMultiMedia referencedObject="MM95"/>
            <paragraph>
              <content styleCode="bold">Important:</content> Store the inhalation device in an upright position until the next treatment session. See "<linkHtml href="#Specifications2">Specifications</linkHtml>" on page 76 for additional storage and transport information.</paragraph>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">B: End of day cleaning</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">If you have completed your last treatment session of the day, perform the steps in this section.</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">If you have more treatment sessions left in the day, refer back to "Storing between sessions during the day" on page 48.</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">1. Disconnect AC wall plug</content>
              <br/>(if it is currently connected)</paragraph>
            <renderMultiMedia referencedObject="MM96"/>
            <paragraph>
              <content styleCode="bold">2. Remove mouthpiece</content>
            </paragraph>
            <renderMultiMedia referencedObject="MM97"/>
            <paragraph>
              <content styleCode="bold">3. Remove inhalation piece with attached filter shell</content>
            </paragraph>
            <renderMultiMedia referencedObject="MM98"/>
            <paragraph>
              <content styleCode="bold">4. Remove both filter shells</content>
            </paragraph>
            <renderMultiMedia referencedObject="MM99"/>
            <paragraph>
              <content styleCode="bold">5. Discard filter membranes</content>
            </paragraph>
            <paragraph>Open filter shells by twisting in opposite directions. Remove and discard used filter membranes in the trash.</paragraph>
            <renderMultiMedia referencedObject="MM100"/>
            <paragraph>
              <content styleCode="bold">6. Remove dome assembly</content>
            </paragraph>
            <paragraph>Remove the dome assembly by turning it counter-clockwise (to the left). The medicine cup should stay attached to the dome assembly.</paragraph>
            <renderMultiMedia referencedObject="MM101"/>
            <paragraph>
              <content styleCode="bold">7. Remove medicine cup</content>
            </paragraph>
            <paragraph>Remove the medicine cup by gently squeezing on the sides where it is attached to the dome assembly.</paragraph>
            <paragraph>Be careful not to spill any leftover medicine.</paragraph>
            <renderMultiMedia referencedObject="MM102"/>
            <paragraph>
              <renderMultiMedia referencedObject="MM4"/> <content styleCode="bold">CAUTION: </content>If any medicine from the medicine cup spills on your hands, wash your hands immediately. Medicine contact with the skin can cause irritation.</paragraph>
            <paragraph>
              <content styleCode="bold">8. Empty medicine cup</content>
            </paragraph>
            <paragraph>Empty any leftover medicine in the medicine cup into a waste basket, and discard the medicine cup.</paragraph>
            <renderMultiMedia referencedObject="MM103"/>
            <paragraph>
              <content styleCode="bold">Important:</content> Discard remaining TYVASO<sup>®</sup> (treprostinil) Inhalation Solution in an appropriate waste receptacle. Discard plastic medicine cup in the trash.</paragraph>
            <paragraph>Do not reuse or recycle medicine cup.</paragraph>
            <paragraph>
              <content styleCode="bold">9. Empty and clean device</content>
            </paragraph>
            <paragraph>Empty distilled water from water chamber and let inhalation device air dry upside down. You can wipe the water chamber with a soft cloth or paper towel to remove any remaining water.</paragraph>
            <renderMultiMedia referencedObject="MM104"/>
            <paragraph>
              <content styleCode="bold">Important:</content> Do not place the inhalation device in water or in a dishwasher.</paragraph>
            <paragraph>
              <content styleCode="bold">10. Clean accessories</content>
            </paragraph>
            <paragraph>Clean accessories (pictured below) by hand in mild, soapy, warm water, then rinse them thoroughly with water. Allow accessories to air dry.</paragraph>
            <table styleCode="Noautorules" width="90%">
              <col align="center" valign="top" width="50%"/>
              <col align="center" valign="top" width="50%"/>
              <tbody>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM105"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM106"/>
                  </td>
                </tr>
                <tr>
                  <td>Dome assembly</td>
                  <td>Inhalation piece</td>
                </tr>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM107"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM108"/>
                  </td>
                </tr>
                <tr>
                  <td>Mouthpiece</td>
                  <td>Filter shells</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content> Do not place the inhalation device or its accessories in a microwave, conventional oven, or dishwasher.</paragraph>
            <paragraph>
              <content styleCode="bold">11. Store components</content>
            </paragraph>
            <paragraph>Once all the items are dry, you can store the filter shells, inhalation piece, mouthpiece, dome assembly, AC wall plug, and inhalation device in the carrying case until the next day's treatment sessions.</paragraph>
            <paragraph>You can also recharge the device for the next day of use (see page 57).</paragraph>
            <renderMultiMedia referencedObject="MM109"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">C: Recharging the battery</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">1. Checking the battery's status</content>
            </paragraph>
            <paragraph>You can recharge your battery at any time. Press and <content styleCode="bold">hold</content> the blue button to power on the device to check battery status. Make sure the Run / Program switch is set to Run.</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>The battery icon at the bottom of the screen indicates battery status:</item>
            </list>
            <renderMultiMedia referencedObject="MM110"/>
            <list listType="unordered" styleCode="disc">
              <item>"Charge battery" appears on screen if there is not enough charge to conduct a treatment session.</item>
            </list>
            <renderMultiMedia referencedObject="MM34"/>
            <paragraph>
              <content styleCode="bold">Important:</content> Always charge the device before you first use it. You should also charge the device when not in use and in between uses.</paragraph>
            <paragraph>
              <content styleCode="bold">2. Charging the battery</content>
            </paragraph>
            <paragraph>Plug the AC wall plug's white connector into the port on the back of the inhalation device. Then, plug the AC wall plug into the wall outlet. The power status light above the port will light green when properly plugged in.</paragraph>
            <paragraph>The device battery might take up to 8 hours to fully charge.</paragraph>
            <paragraph>If the device is powered on, the battery charging icon appears next to the battery icon at the bottom of the screen.</paragraph>
            <table styleCode="Noautorules" width="100%">
              <col align="center" valign="top" width="100%"/>
              <tbody>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM111"/>
                  </td>
                </tr>
                <tr>
                  <td>Battery charging icon</td>
                </tr>
              </tbody>
            </table>
            <renderMultiMedia referencedObject="MM112"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">D: Weekly cleaning</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>Clean the device once a week to help avoid corrosion and leaks and to keep your device working properly.</paragraph>
            <paragraph>Once a week, use a clean, dry cloth to wipe the interior of the water chamber. Make sure to wipe the 2 silver sensors and the white disc in the bottom of the water chamber.</paragraph>
            <renderMultiMedia referencedObject="MM113"/>
            <paragraph>You may wipe the exterior of the device with a damp cloth if the lights or buttons become difficult to see.</paragraph>
            <renderMultiMedia referencedObject="MM114"/>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">E: Monthly Refill Kit</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>Once a month, you will receive a refill kit that will come with a new set of accessories from your specialty pharmacy provider.</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Inspect the shipment to be sure all parts are included.</item>
              <item>Once the new kit has arrived, discard the used dome assembly, inhalation piece, mouthpiece, filter shells, and plugs.</item>
              <item>Do not recycle the used accessories.</item>
            </list>
            <table styleCode="Noautorules" width="75%">
              <col align="center" valign="top" width="34%"/>
              <col align="center" valign="top" width="33%"/>
              <col align="center" valign="top" width="33%"/>
              <tbody>
                <tr>
                  <td align="right">
                    <renderMultiMedia referencedObject="MM115"/>
                  </td>
                  <td align="center" colspan="2">
                    <renderMultiMedia referencedObject="MM116"/>
                  </td>
                </tr>
                <tr>
                  <td align="center">Dome assembly</td>
                  <td colspan="2">2 filter shells</td>
                </tr>
                <tr>
                  <td>
                    <renderMultiMedia referencedObject="MM117"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM118"/>
                  </td>
                  <td>
                    <renderMultiMedia referencedObject="MM119"/>
                  </td>
                </tr>
                <tr>
                  <td>Mouthpiece</td>
                  <td>Inhalation piece</td>
                  <td>2 plugs</td>
                </tr>
                <tr>
                  <td align="right">
                    <renderMultiMedia referencedObject="MM120"/>
                  </td>
                  <td align="center" colspan="2">
                    <renderMultiMedia referencedObject="MM121"/>
                  </td>
                </tr>
                <tr>
                  <td align="center">Filter membranes</td>
                  <td colspan="2">Medicine cups</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">F: Replacing your devices</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>The inhalation devices should be replaced every 2 years from your first day of use. Replacement inhalation devices will be supplied by your specialty pharmacy provider.</paragraph>
            <paragraph>When you receive a new inhalation device your specialty pharmacy provider will provide instructions for returning the old device.</paragraph>
            <paragraph>
              <content styleCode="bold">Help / More information about your TYVASO Inhalation System</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Section overview</content>
            </paragraph>
            <paragraph>This section provides additional information about your device. Use this section to troubleshoot difficulties you have with the device, or to learn more about the device's specifications and warranty.</paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>What you will need:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  ▶ Access to a phone (to contact support if troubleshooting steps do not resolve the problem)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ A clean place to work with the device</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  ▶ TYVASO Inhalation Device or supplies, as needed</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="80%"/>
              <col align="right" valign="bottom" width="20%"/>
              <thead>
                <tr>
                  <th colspan="2">What is covered in this section:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>  A: Troubleshooting</td>
                  <td>64</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  B: Specifications</td>
                  <td>76</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  C: Electromagnetic compatibility (EMC)</td>
                  <td>79</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  D: Glossary</td>
                  <td>87</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>  E: Warranty information</td>
                  <td>90</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Important:</content>
            </paragraph>
            <paragraph>For further support, you can:</paragraph>
            <list listType="unordered" styleCode="disc">
              <item>Fill out and refer to your emergency contact information on the back of this Instructions for Use manual.</item>
              <item>Call 1-844-UNITHER (1-844-864-8437) for questions and information, or to report an adverse reaction.</item>
            </list>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">A: Troubleshooting</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table ID="Troubleshooting" width="100%">
              <col align="left" valign="top" width="30%"/>
              <col align="left" valign="top" width="35%"/>
              <col align="left" valign="top" width="35%"/>
              <thead>
                <tr>
                  <th>Problem</th>
                  <th>Possible causes</th>
                  <th>Corrective actions</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td rowspan="4">
                    <content styleCode="bold">Charge Battery screen appears<br/>
                      <renderMultiMedia referencedObject="MM34"/>
                    </content>
                  </td>
                  <td styleCode="Botrule">Low battery</td>
                  <td styleCode="Botrule">Charge the device battery by attaching the AC wall plug to an outlet. You can conduct a treatment session with the device plugged in.</td>
                </tr>
                <tr>
                  <td>AC wall plug not properly connected<br/>
                    <renderMultiMedia referencedObject="MM122"/>
                  </td>
                  <td>Ensure that the plug adapter piece (the detachable piece with the metal prongs) is securely attached to the AC wall plug. Then, make sure the AC wall plug is properly connected to an outlet and device. The status lights on the back of the AC wall plug and device should light green. You can conduct a treatment session with the device plugged in.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">AC wall plug is defective<br/>
                    <renderMultiMedia referencedObject="MM123"/>
                  </td>
                  <td styleCode="Botrule">Use the replacement AC wall plug. Confirm that status light on AC wall plug is green when plugged in. You can conduct a treatment session with the device plugged in.</td>
                </tr>
                <tr>
                  <td colspan="2">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="4">
                    <content styleCode="bold">Screen does not turn on<br/>
                      <renderMultiMedia referencedObject="MM124"/>
                    </content>
                  </td>
                  <td styleCode="Botrule">Device battery is completely empty</td>
                  <td styleCode="Botrule">Charge the device battery by attaching the AC wall plug to an outlet. You can conduct a treatment session with the device plugged in.</td>
                </tr>
                <tr>
                  <td>AC wall plug not properly connected<br/>
                    <renderMultiMedia referencedObject="MM122a"/>
                  </td>
                  <td>Ensure that the plug adapter piece (the detachable piece with the metal prongs) is securely attached to the AC wall plug. Then, make sure the AC wall plug is properly connected to an outlet and device. The status lights on the back of the AC wall plug and device should light green. You can conduct a treatment session with the device plugged in.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">AC wall plug is defective<br/>
                    <renderMultiMedia referencedObject="MM125"/>
                  </td>
                  <td styleCode="Botrule">Use the replacement AC wall plug. Confirm that status light on AC wall plug is green when plugged in. You can conduct a treatment session with the device plugged in.</td>
                </tr>
                <tr>
                  <td colspan="2" styleCode="Botrule">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="2">
                    <content styleCode="bold">Call Support screen appears<br/>
                      <renderMultiMedia referencedObject="MM31"/>
                    </content>
                  </td>
                  <td styleCode="Botrule">Temporary device failure.</td>
                  <td styleCode="Botrule">If device is plugged in, unplug device and wait for the device to power off. Power on device from internal battery and check that Call Support screen does not reappear. Continue taking breaths to complete the treatment session.</td>
                </tr>
                <tr>
                  <td colspan="2">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="3">
                    <content styleCode="bold">Loss of power during treatment</content>
                  </td>
                  <td styleCode="Botrule">Device is disconnected from power source and battery is empty</td>
                  <td styleCode="Botrule">Reconnect device to power source and confirm the power status light on back of device is green (battery is charging). Press and <content styleCode="bold">hold</content> the blue On/Off button to turn on the device. The display will show how many breaths are left in that treatment session. Press <content styleCode="bold">and immediately</content> release (do not hold down) the blue button again to continue your treatment session.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">Power source is temporarily disrupted (for example, electricity interruption due to a storm)</td>
                  <td styleCode="Botrule">Reconnect device to power source and confirm the power status light on back of device is green (battery is charging). Press and <content styleCode="bold">hold</content> the blue On/Off button to turn on the device. The display will show how many breaths are left in that treatment session. Press <content styleCode="bold">and immediately</content> release (do not hold down) the blue button again to continue your treatment session.</td>
                </tr>
                <tr>
                  <td colspan="2">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="4">
                    <content styleCode="bold">Add Water screen appears<br/>
                      <renderMultiMedia referencedObject="MM33"/>
                    </content>
                  </td>
                  <td>Water chamber is empty or distilled water level is too low.<br/>
                    <renderMultiMedia referencedObject="MM126"/>
                  </td>
                  <td>Unplug device, if plugged in, and power off device. Remove dome assembly (making sure not to spill medicine) and place it aside, keeping it upright. Then empty water chamber.<br/>Refill water chamber with distilled water using water level cup (see page 32). Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td>The distilled water is too pure.</td>
                  <td>Unplug device, if plugged in, and power off device. Remove dome assembly (making sure not to spill medicine) and place it aside, keeping it upright. Then empty water chamber.<br/>Add 1 teaspoon of tap water to the water level cup. Fill rest of cup with distilled water up to level between the 2 arrow markings on cup (see page 32). Pour cup's contents into water chamber. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">Water level sensors have a thin layer of build-up<br/>
                    <renderMultiMedia referencedObject="MM127"/>
                  </td>
                  <td styleCode="Botrule">Unplug device, if plugged in, and power off device. Remove dome assembly (making sure not to spill medicine) and place it aside, keeping it upright. Then empty water chamber.<br/>Clean sensors and interior surfaces of water chamber with a clean cloth. Refill water chamber with distilled water using water level cup (see page 32). Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td colspan="2">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="5">
                    <content styleCode="bold">No "click" (or crunch) was heard when attaching the dome assembly 					</content>
                  </td>
                  <td styleCode="Botrule">No medicine cup in the water chamber of the device</td>
                  <td styleCode="Botrule">Unplug device, if plugged in, and power off device. Place an empty medicine cup into the water chamber of the device and fill it with 1 ampule of TYVASO. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td>Multiple medicine cups attached to the dome assembly<br/>
                    <renderMultiMedia referencedObject="MM128"/>
                  </td>
                  <td>Unplug device, if plugged in, and power off device. Remove and dispose of all medicine cups in the device. Place a single, new medicine cup into device water chamber and fill with 1 ampule of TYVASO. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td>Dome assembly is not securely in place</td>
                  <td>Unplug device, if plugged in, and power off device.<br/>Align the raised circle on the side of the dome assembly with the raised circle on the side of the device.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">
                    <renderMultiMedia referencedObject="MM129"/>
                  </td>
                  <td styleCode="Botrule">Push down and screw the dome assembly onto the device clockwise (right) until the filter shell port is tight and pointed to the back of the device and the raised circles line up again. You will hear clicks (or crunch sound) as the dome assembly presses down on the medicine cup. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td colspan="2">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="5">
                    <content styleCode="bold">No medicine comes out of the device during a treatment session 					</content>
                  </td>
                  <td styleCode="Botrule">No TYVASO<sup>®</sup> (treprostinil) Inhalation Solution in the medicine cup<br/>
                    <renderMultiMedia referencedObject="MM130"/>
                  </td>
                  <td styleCode="Botrule">Unplug device, if plugged in, and power off device. Fill medicine cup with 1 ampule of TYVASO. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">Damaged medicine cup<br/>
                    <renderMultiMedia referencedObject="MM131"/>
                  </td>
                  <td styleCode="Botrule">Unplug device, if plugged in, and power off device. Remove and dispose of the medicine cup in the device. Empty the water chamber then refill it with 45 mL of distilled water (see page 32). Place a single, new medicine cup into water chamber and fill with 1 ampule of TYVASO. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td>Distilled water level in the water chamber is too high<br/>
                    <renderMultiMedia referencedObject="MM132"/>
                  </td>
                  <td>Unplug device, if plugged in, and power off device. Remove dome assembly (making sure not to spill medicine) and place it aside, keeping it upright. Empty the water chamber then refill it with 45 mL of distilled water (see page 32). Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td styleCode="Botrule">Multiple medicine cups attached to the dome assembly<br/>
                    <renderMultiMedia referencedObject="MM133"/>
                  </td>
                  <td styleCode="Botrule">Unplug device, if plugged in, and power off device. Remove and dispose of all medicine cups in the device. Place a single, new medicine cup into water chamber and fill with 1 ampule of TYVASO. Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td colspan="2" styleCode="Botrule">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
                <tr>
                  <td rowspan="2">
                    <content styleCode="bold">Difficult to breathe in medicine through the mouthpiece</content>
                  </td>
                  <td styleCode="Botrule">Filter membrane is clogged<br/>
                    <renderMultiMedia referencedObject="MM134"/>
                  </td>
                  <td styleCode="Botrule">Unplug device, if plugged in, and power off device. Replace both filter membranes (see page 37). Reassemble device. Power the device on and continue treatment.</td>
                </tr>
                <tr>
                  <td colspan="2">If device still does not function after taking corrective actions listed above, contact your specialty pharmacy provider for assistance.</td>
                </tr>
              </tbody>
            </table>
            <table ID="Specifications2" styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">B: Specifications</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table width="90%">
              <col align="left" valign="top" width="50%"/>
              <col align="left" valign="top" width="50%"/>
              <thead>
                <tr>
                  <th colspan="2">Inhalation Device</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>Model</td>
                  <td>
                    <content styleCode="bold">TD-300/A</content>
                  </td>
                </tr>
                <tr>
                  <td>Size</td>
                  <td>
                    <content styleCode="bold">3.5" × 3.2" × 4.7" (90 × 82 × 120 mm)</content>
                  </td>
                </tr>
                <tr>
                  <td>Weight, inhalation device</td>
                  <td>
                    <content styleCode="bold">365 g (12.8 oz)</content>
                  </td>
                </tr>
                <tr>
                  <td>Types of power supply</td>
                  <td>
                    <content styleCode="bold">AC wall plug, 120 V, 60 Hz</content>
                  </td>
                </tr>
                <tr>
                  <td>Power input</td>
                  <td>
                    <content styleCode="bold">14 V DC, 1.1 A maximum</content>
                  </td>
                </tr>
                <tr>
                  <td>Operating power consumption</td>
                  <td>
                    <content styleCode="bold">18 Watt maximum</content>
                  </td>
                </tr>
                <tr>
                  <td>Ultrasonic frequency</td>
                  <td>
                    <content styleCode="bold">2.4 MHz (nominal)</content>
                  </td>
                </tr>
                <tr>
                  <td>Nebulization rate</td>
                  <td>
                    <content styleCode="bold">0.50 - 0.55 mg/min (0.9% Saline)</content>
                  </td>
                </tr>
                <tr>
                  <td>Medicine cup capacity</td>
                  <td>
                    <content styleCode="bold">6 mL, nominal</content>
                  </td>
                </tr>
                <tr>
                  <td>Water chamber capacity</td>
                  <td>
                    <content styleCode="bold">45 mL, nominal</content>
                  </td>
                </tr>
                <tr>
                  <td>Electric protection class</td>
                  <td>
                    <content styleCode="bold">II, Type BF</content>
                  </td>
                </tr>
                <tr>
                  <td>Storage temperature/humidity</td>
                  <td>
                    <content styleCode="bold">15 to 30ºC/20-80% relative humidity</content>
                  </td>
                </tr>
                <tr>
                  <td>Operating temperature/humidity</td>
                  <td>
                    <content styleCode="bold">15 to 25ºC/40-75% relative humidity</content>
                  </td>
                </tr>
                <tr>
                  <td>A-weighted sound pressure level</td>
                  <td>
                    <content styleCode="bold">75 dBA (1 m), maximum</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table width="60%">
              <col align="left" valign="top" width="60%"/>
              <col align="left" valign="top" width="40%"/>
              <thead>
                <tr>
                  <th colspan="2">Packaging Dimensions (Approximate Length × Width × Height)</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>Patient Starter Kit (PSK)</td>
                  <td>
                    <content styleCode="bold">13.0" × 12.4" × 9.2"</content>
                  </td>
                </tr>
                <tr>
                  <td>Monthly Refill Kit (MRK)</td>
                  <td align="left">
                    <content styleCode="bold">11.8" × 8.2" × 3.0"</content>
                  </td>
                </tr>
                <tr>
                  <td>Institutional Starter Kit (ISK)</td>
                  <td>
                    <content styleCode="bold">13.0" × 12.4" × 9.2"</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table width="60%">
              <col align="left" valign="top" width="60%"/>
              <col align="left" valign="top" width="40%"/>
              <thead>
                <tr>
                  <th colspan="2">TYVASO Mass and Particle Specifications for 9 breaths</th>
                </tr>
              </thead>
              <tbody>
                <tr>
                  <td>Mass Median Aerodynamic Diameter (MMAD)<footnote ID="footspec1">n=108 data points from r=3 inhalation devices. Each data point was 9 breaths.</footnote>
                  </td>
                  <td>
                    <content styleCode="bold">mean = 2.0 µm<br/>SD = 0.3</content>
                  </td>
                </tr>
                <tr>
                  <td>Total Emitted Dose per Breath<footnote ID="footspec2">n=216 data points from r=6 inhalation devices. Each data point was 1 breath.</footnote>
                  </td>
                  <td>
                    <content styleCode="bold">mean = 6.0 µg<br/>SD = 0.4</content>
                  </td>
                </tr>
                <tr>
                  <td>Total Aerosol Mass<footnoteRef IDREF="footspec1"/>
                  </td>
                  <td>
                    <content styleCode="bold">mean = 58 µg<br/>SD = 5.9</content>
                  </td>
                </tr>
                <tr>
                  <td>Total Respirable Dose<footnoteRef IDREF="footspec1"/>
                  </td>
                  <td>
                    <content styleCode="bold">mean = 44.6 µg<br/>SD = 3.5</content>
                  </td>
                </tr>
                <tr>
                  <td>Respirable Fraction<footnoteRef IDREF="footspec1"/>
                  </td>
                  <td>
                    <content styleCode="bold">mean = 73%<br/>SD = 5</content>
                  </td>
                </tr>
                <tr>
                  <td>Geometric Standard Deviation (GSD)<footnoteRef IDREF="footspec1"/>
                  </td>
                  <td>
                    <content styleCode="bold">mean = 2.6<br/>SD = 0.4</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table width="60%">
              <col align="left" valign="top" width="30%"/>
              <col align="left" valign="top" width="70%"/>
              <thead>
                <tr>
                  <th colspan="2">Accessories</th>
                </tr>
              </thead>
              <tfoot>
                <tr>
                  <td align="left" colspan="2">Note: Part number subject to change.</td>
                </tr>
              </tfoot>
              <tbody>
                <tr>
                  <td>TD-300N-US</td>
                  <td>
                    <content styleCode="bold">AC wall plug</content>
                  </td>
                </tr>
                <tr>
                  <td>TD-132</td>
                  <td>
                    <content styleCode="bold">Medicine cup, Quantity - 32</content>
                  </td>
                </tr>
                <tr>
                  <td>ON-109</td>
                  <td>
                    <content styleCode="bold">Filter membranes</content>
                  </td>
                </tr>
                <tr>
                  <td>ON-120/C</td>
                  <td>
                    <content styleCode="bold">Plugs</content>
                  </td>
                </tr>
                <tr>
                  <td>ON-101/C</td>
                  <td>
                    <content styleCode="bold">Filter shell</content>
                  </td>
                </tr>
                <tr>
                  <td>TD-103/C</td>
                  <td>
                    <content styleCode="bold">Dome assembly with baffle plate</content>
                  </td>
                </tr>
                <tr>
                  <td>ON-104/C</td>
                  <td>
                    <content styleCode="bold">Inhalation piece</content>
                  </td>
                </tr>
                <tr>
                  <td>ON-105/C</td>
                  <td>
                    <content styleCode="bold">Mouthpiece</content>
                  </td>
                </tr>
                <tr>
                  <td>TD-118</td>
                  <td>
                    <content styleCode="bold">Water level cup</content>
                  </td>
                </tr>
                <tr>
                  <td>TD-158</td>
                  <td>
                    <content styleCode="bold">Carrying case</content>
                  </td>
                </tr>
                <tr>
                  <td>TD-155</td>
                  <td>
                    <content styleCode="bold">Distilled water carrier</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">C: Electromagnetic compatibility (EMC)</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>The TYVASO Inhalation System has been tested and found to comply with the electromagnetic compatibility (EMC) limits for medical devices according to IEC 60601-1-2: (2007). Compliance is intended to provide reasonable protection against harmful interference in a typical user environment.</paragraph>
            <paragraph>Table 1, Table 2 and Table 3 document the intended EMC use environment and established compliance levels for the TYVASO Inhalation System. To ensure the intended performance, use the system in the environments described in these tables.</paragraph>
            <paragraph>The TYVASO Inhalation System is intended for use in the electromagnetic environment specified in this section.</paragraph>
            <table width="100%">
              <caption>Table 1: Guidance and manufacturer's declaration - electromagnetic emissions</caption>
              <col align="left" valign="top" width="15%"/>
              <col align="center" valign="top" width="15%"/>
              <col align="left" valign="top" width="70%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td align="center" colspan="3" styleCode="Lrule Rrule">
                    <content styleCode="bold">Guidance and manufacturer's declaration - electromagnetic emissions</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td colspan="3" styleCode="Lrule Rrule">The TYVASO Inhalation System is intended for use in the electromagnetic environment specified below. The customer or the user of the TYVASO Inhalation System should assure that it is used in such an environment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td align="center" styleCode="Lrule Rrule">
                    <content styleCode="bold">Emissions test</content>
                  </td>
                  <td align="center" styleCode="Rrule">
                    <content styleCode="bold">Compliance</content>
                  </td>
                  <td align="center" styleCode="Rrule">
                    <content styleCode="bold">Electromagnetic environment - guidance</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">RF emissions CISPR 11</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Group 1</content>
                  </td>
                  <td styleCode="Rrule">The TYVASO Inhalation System uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">RF emissions CISPR 11</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Class B</content>
                  </td>
                  <td rowspan="3" styleCode="Rrule">The TYVASO Inhalation System is suitable for use in all establishments, including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Harmonic emissions IEC 61000-3-2</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Class A</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Voltage fluctuations/flicker emissions IEC 61000-3-3</td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">Complies</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <table width="100%">
              <caption>Table 2: Guidance and manufacturer's declaration – electromagnetic immunity</caption>
              <col align="left" valign="top" width="20%"/>
              <col align="left" valign="top" width="20%"/>
              <col align="left" valign="top" width="20%"/>
              <col align="left" valign="top" width="40%"/>
              <tfoot>
                <tr>
                  <td align="left" colspan="4">NOTE: <content styleCode="italics">U</content>
                    <sub>T</sub> is the a.c. mains voltage prior to application of the test level.<br/>NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.<br/>NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.</td>
                </tr>
              </tfoot>
              <tbody>
                <tr styleCode="Botrule">
                  <td align="center" colspan="4" styleCode="Lrule Rrule">
                    <content styleCode="bold">Guidance and manufacturer's declaration – electromagnetic immunity</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td colspan="4" styleCode="Lrule Rrule">The TYVASO Inhalation System is intended for use in the electromagnetic environment specified below. The customer or the user of the TYVASO Inhalation System should assure that it is used in such an environment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td align="center" styleCode="Lrule Rrule">
                    <content styleCode="bold">Immunity test</content>
                  </td>
                  <td align="center" styleCode="Rrule">
                    <content styleCode="bold">IEC 60601 Test level</content>
                  </td>
                  <td align="center" styleCode="Rrule">
                    <content styleCode="bold">Compliance level</content>
                  </td>
                  <td align="center" styleCode="Rrule">
                    <content styleCode="bold">Electromagnetic environment - guidance</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Electrostatic discharge (ESD)<br/>IEC 61000-4-2</td>
                  <td styleCode="Rrule">± 8 kV contact<br/>± 15 kV air</td>
                  <td styleCode="Rrule">± 8 kV contact<br/>± 15 kV air</td>
                  <td styleCode="Rrule">Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Electrical fast transient/burst<br/>IEC 61000-4-4</td>
                  <td styleCode="Rrule">± 2 kV for power supply lines<br/>± 1 kV for input/output lines</td>
                  <td styleCode="Rrule">± 2 kV for power supply lines<br/>± 1 kV for input/output lines</td>
                  <td styleCode="Rrule">Mains power quality should be that of a typical commercial or hospital environment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Surge<br/>IEC 61000-4-5</td>
                  <td styleCode="Rrule">± 1 kV line(s) to line(s)<br/>± 2 kV line(s) to earth</td>
                  <td styleCode="Rrule">± 1 kV line(s) to line(s)<br/>± 2 kV line(s) to earth</td>
                  <td styleCode="Rrule">Mains power quality should be that of a typical commercial or hospital environment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Voltage dips, short interruptions and voltage variations on power supply input lines<br/>IEC 61000-4-11</td>
                  <td styleCode="Rrule">									0 % <content styleCode="italics">U</content>
                    <sub>T</sub> (100 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 0,5 cycle<br/>									0 % <content styleCode="italics">U</content>
                    <sub>T</sub> (100 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 1 cycle<br/>									70 % <content styleCode="italics">U</content>
                    <sub>T</sub> (30 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 25/30 cycles<br/>									0 % <content styleCode="italics">U</content>
                    <sub>T</sub> (100 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 250/300 cycle</td>
                  <td styleCode="Rrule">									0 % <content styleCode="italics">U</content>
                    <sub>T</sub> (100 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 0,5 cycle<br/>									0 % <content styleCode="italics">U</content>
                    <sub>T</sub> (100 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 1 cycle<br/>									70 % <content styleCode="italics">U</content>
                    <sub>T</sub> (30 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 25/30 cycles<br/>									0 % <content styleCode="italics">U</content>
                    <sub>T</sub> (100 % dip in <content styleCode="italics">U</content>
                    <sub>T</sub>) for 250/300 cycle</td>
                  <td styleCode="Rrule">Mains power quality should be that of a typical commercial or hospital environment. If the user of the TYVASO Inhalation System requires continued operation during power mains interruptions, it is recommended that the TYVASO Inhalation System be powered from an uninterruptible power supply or the internal battery.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Power frequency (50/60 Hz) magnetic field<br/>IEC 61000-4-8</td>
                  <td styleCode="Rrule">30 A/m</td>
                  <td styleCode="Rrule">30 A/m</td>
                  <td styleCode="Rrule">Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">Conducted RF<br/>IEC 61000-4-6<br/>Radiated RF<br/>IEC 61000-4-3</td>
                  <td styleCode="Rrule">3 Vrms 150 kHz to 80 MHz<br/>10 V/m 80 MHz to 2.6 GHz</td>
                  <td styleCode="Rrule">3 Vrms 150 kHz to 80 MHz<br/>10 V/m 80 MHz to 2.6 GHz</td>
                  <td styleCode="Rrule">Portable and mobile RF communications equipment should be used no closer to any part of TYVASO Inhalation System, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.<br/>
                    <content styleCode="bold">Recommended separation distance</content>
                    <br/>
                    <content styleCode="italics">d</content> = 1.2 √<content styleCode="italics">P</content>
                    <br/>
                    <content styleCode="italics">d</content> = 1.2 √<content styleCode="italics">P</content> 80 MHz to 800 MHz<br/>
                    <content styleCode="italics">d</content> = 2.3 √<content styleCode="italics">P</content> 800 MHz to 2.5 GHz<br/>where <content styleCode="italics">P</content> is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and <content styleCode="italics">d</content> is the recommended separation distance in meters (m).<br/>Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey<footnote>Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the TYVASO Inhalation System is used exceeds the applicable RF compliance level above, the TYVASO Inhalation System should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the TYVASO Inhalation System.</footnote>, should be less than the compliance level in each frequency range<footnote>Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V1] V/m.</footnote>.<br/>Interference may occur in the vicinity of equipment marked with the following symbol: <renderMultiMedia referencedObject="MM135"/>
                  </td>
                </tr>
              </tbody>
            </table>
            <table width="100%">
              <caption>Table 3: Manufacturer's Declaration – Recommended separation distances between portable and mobile communications equipment and the TYVASO Inhalation System</caption>
              <col align="center" valign="top" width="25%"/>
              <col align="center" valign="top" width="25%"/>
              <col align="center" valign="top" width="25%"/>
              <col align="center" valign="top" width="25%"/>
              <tfoot>
                <tr>
                  <td align="left" colspan="4">For transmitters rated at a maximum output power not listed above, the recommended separation distance <content styleCode="italics">d</content> in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where <content styleCode="italics">P</content> is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.<br/> NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.<br/> NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.</td>
                </tr>
              </tfoot>
              <tbody>
                <tr styleCode="Botrule">
                  <td colspan="4" styleCode="Lrule Rrule">
                    <content styleCode="bold">Recommended separation distances between portable and mobile RF communications equipment and the TYVASO Inhalation System</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td align="left" colspan="4" styleCode="Lrule Rrule">The TYVASO Inhalation System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the TYVASO Inhalation System can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the TYVASO Inhalation System as recommended below, according to the maximum output power of the communications equipment.</td>
                </tr>
                <tr styleCode="Botrule">
                  <td rowspan="2" styleCode="Lrule Rrule">
                    <content styleCode="bold">Rated maximum output power of transmitter</content>
                    <br/>W</td>
                  <td colspan="3" styleCode="Rrule">
                    <content styleCode="bold">Separation distance according to frequency of transmitter</content>
                    <br/>m</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">
                    <content styleCode="bold">150 kHz to 80 MHz</content>
                    <br/>
                    <content styleCode="italics">d</content> = 1.2 √<content styleCode="italics">P</content>
                  </td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">80 MHz to 800 MHz</content>
                    <br/>
                    <content styleCode="italics">d</content> = 1.2 √<content styleCode="italics">P</content>
                  </td>
                  <td styleCode="Rrule">
                    <content styleCode="bold">800 MHz to 2.5 GHz</content>
                    <br/>
                    <content styleCode="italics">d</content> = 2.3 √<content styleCode="italics">P</content>
                  </td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">0.01</td>
                  <td styleCode="Rrule">0.12</td>
                  <td styleCode="Rrule">0.12</td>
                  <td styleCode="Rrule">0.23</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">0.1</td>
                  <td styleCode="Rrule">0.38</td>
                  <td styleCode="Rrule">0.38</td>
                  <td styleCode="Rrule">0.73</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">1</td>
                  <td styleCode="Rrule">1.2</td>
                  <td styleCode="Rrule">1.2</td>
                  <td styleCode="Rrule">2.3</td>
                </tr>
                <tr styleCode="Botrule">
                  <td styleCode="Lrule Rrule">10</td>
                  <td styleCode="Rrule">3.8</td>
                  <td styleCode="Rrule">3.8</td>
                  <td styleCode="Rrule">7.3</td>
                </tr>
                <tr>
                  <td styleCode="Lrule Rrule">100</td>
                  <td styleCode="Rrule">12</td>
                  <td styleCode="Rrule">12</td>
                  <td styleCode="Rrule">23</td>
                </tr>
              </tbody>
            </table>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">D: Glossary</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Accessories: </content>Parts of the TYVASO Inhalation System. See page 29.</paragraph>
            <paragraph>
              <content styleCode="bold">Ampule: </content>A sealed, lightweight clear plastic vial containing a 1-day supply of TYVASO<sup>®</sup> (treprostinil) Inhalation Solution.</paragraph>
            <paragraph>
              <content styleCode="bold">Black ring: </content>A round seal that fits on the bottom of the dome assembly. The seal helps ensure that TYVASO does not mix with the distilled water in the device water chamber.</paragraph>
            <paragraph>
              <content styleCode="bold">Display screen: </content>A small area on the inhalation device that provides instructions and device information.</paragraph>
            <paragraph>
              <content styleCode="bold">Distilled water: </content>Water that is highly purified so that it contains only essential elements.</paragraph>
            <paragraph>
              <content styleCode="bold">Dome assembly: </content>The plastic accessory that contains the baffle plate and connects the mouthpiece, inhalation piece, and filter shells to the base of the inhalation device.</paragraph>
            <paragraph>
              <content styleCode="bold">Filter membrane: </content>The white pad that goes into the filter shells.</paragraph>
            <paragraph>
              <content styleCode="bold">Filter shells: </content>Plastic accessories that hold the filter membranes.</paragraph>
            <paragraph>
              <content styleCode="bold">Inhalation indicator lights: </content>Two green lights on the top surface of the inhalation device that signals when you should inhale.</paragraph>
            <paragraph>
              <content styleCode="bold">Inhalation piece: </content>The plastic accessory that connects the mouthpiece with the dome assembly.</paragraph>
            <paragraph>
              <content styleCode="bold">Inhalation device: </content>The base of the TYVASO Inhalation System to which the accessories connect. The inhalation device contains the display screen and lights.</paragraph>
            <paragraph>
              <content styleCode="bold">Inhale: </content>How you will breathe in TYVASO with the TYVASO Inhalation System.</paragraph>
            <paragraph>
              <content styleCode="bold">Medicine cup: </content>The disposable plastic cone-shaped cup into which TYVASO is poured. The medicine cup fits inside the water chamber.</paragraph>
            <paragraph>
              <content styleCode="bold">Mouthpiece: </content>The plastic part that you will breathe through (using your mouth) to inhale TYVASO.</paragraph>
            <paragraph>
              <content styleCode="bold">On/Off, Start/Pause (blue) button: </content>A manually activated control on the front of the device that switches between fully on and fully off power states. Once the device power is on, the button begins or pauses treatment.</paragraph>
            <paragraph>
              <content styleCode="bold">Plugs: </content>Plastic accessories that are inserted into the openings of the dome assembly between treatment sessions. Plugs help keep TYVASO from spilling if the inhalation device tips over.</paragraph>
            <paragraph>
              <content styleCode="bold">Power status light: </content>LED on the back of the device that lights green when power is connected and battery is charging.</paragraph>
            <paragraph>
              <content styleCode="bold">Power port: </content>Port on back of device for plugging into a power source using the AC wall plug.</paragraph>
            <paragraph>
              <content styleCode="bold">Prompts: </content>The audio and visual signals that help guide you through the treatment sessions.</paragraph>
            <paragraph>
              <content styleCode="bold">Run / Program switch: </content>A manually activated control on the side of the device that switches between the modes for delivering treatment (Run) and programming breaths (Program).</paragraph>
            <paragraph>
              <content styleCode="bold">Sensors: </content>The silver objects on the inside wall of the water chamber. The sensors must be covered with distilled water for the TYVASO Inhalation System to function properly.</paragraph>
            <paragraph>
              <content styleCode="bold">Specialty pharmacy provider: </content>A pharmacy that carries only specialized medicines and medical devices. Your specialty pharmacy provider is a good source of information about TYVASO and the TYVASO Inhalation System.</paragraph>
            <paragraph>
              <content styleCode="bold">Treatment session: </content>1 of 4 daily sessions during which you will take TYVASO with a specific number of inhalations.</paragraph>
            <paragraph>
              <content styleCode="bold">TYVASO: </content>The prescription medicine that you will use with the TYVASO Inhalation System.</paragraph>
            <paragraph>
              <content styleCode="bold">Volume / Breaths toggle button: </content>A manually activated control on the side of the device that increases or decreases audio volume (when in Run mode) and programmed breaths (when in Program mode).</paragraph>
            <paragraph>
              <content styleCode="bold">Water chamber: </content>The white hollow portion in the center of the inhalation device into which distilled water and the medicine cup are placed.</paragraph>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <tbody>
                <tr styleCode="Botrule">
                  <td>
                    <content styleCode="bold">E: Warranty information</content>
                  </td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">Your TYVASO Inhalation System is granted a replacement or repair warranty good for 2 years from your date of receipt of the TYVASO Inhalation System or 5 years from the date of manufacture, whichever comes first. This warranty applies to the TYVASO Inhalation System device only. Accessory components are not covered under warranty.</content>
            </paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>Circumstances that may void your warranty include:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>▶ Modification or disassembly of the TYVASO Inhalation System device by anyone other than a factory-authorized technician</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ Failure to comply with this written Instructions for Use manual when operating the TYVASO Inhalation System</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ Unapproved use of the TYVASO Inhalation System</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">For all inquiries relating to service or warranty for your TYVASO Inhalation System, contact your specialty pharmacy provider.</content>
            </paragraph>
            <table styleCode="Noautorules" width="50%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>You should have the following information available:</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>▶ Device serial number (located on bottom of TYVASO Inhalation System)</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ Date TYVASO Inhalation System was acquired</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ Nature of the problem and any steps taken to fix it</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold italics">TYVASO</content>
              <sup> ®</sup>
              <br/>
              <content styleCode="bold italics">INHALATION SYSTEM</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold italics">TYVASO</content>
              <sup>®</sup>
              <br/>
              <content styleCode="italics">(treprostinil)<br/>
                <content styleCode="bold">INHALATION<br/>SOLUTION</content>
              </content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">TYVASO Inhalation Solution is for prescription use only.</content>
            </paragraph>
            <table styleCode="Noautorules" width="100%">
              <col align="left" valign="bottom" width="100%"/>
              <thead>
                <tr>
                  <th>Emergency contact information</th>
                </tr>
              </thead>
              <tbody>
                <tr styleCode="Botrule">
                  <td>▶ Clinician:</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ Nurse educator:</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ Specialty pharmacist:</td>
                </tr>
                <tr styleCode="Botrule">
                  <td>▶ United Therapeutics:</td>
                </tr>
              </tbody>
            </table>
            <paragraph>
              <content styleCode="bold">For further questions and information, or to report a problem with your device or an adverse event with your TYVASO Inhalation System, please call 1-844-UNITHER (1-844-864-8437).</content>
            </paragraph>
            <paragraph>
              <content styleCode="bold">Distributed by:</content>
              <br/>United Therapeutics Corporation<br/>Durham, North Carolina 27713</paragraph>
            <paragraph>© 2025, United Therapeutics Corporation.<br/>All rights reserved.</paragraph>
            <paragraph>
              <content styleCode="bold">102131</content>
            </paragraph>
            <paragraph>TYVASO is a registered trademark of<br/>United Therapeutics Corporation.</paragraph>
            <paragraph>This Instructions for Use has been<br/>approved by the U.S. Food and Drug<br/>Administration.</paragraph>
            <paragraph>Revised: October 2025</paragraph>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM4">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-04.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM5">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-05.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM6">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-06.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM7">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-07.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM8">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-08.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM9">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-09.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM10">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-10.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM11">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-11.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM12">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-12.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM13">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-13.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM14">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-14.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM15">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-15.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM16">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-16.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM17">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-17.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM18">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-18.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM19">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-19.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM20">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-20.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM21">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-21.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM22">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-22.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM23">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-23.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM24">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-24.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM25">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-25.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM26">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-26.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM27">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-27.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM28">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-28.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM29">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-29.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM30">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-30.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM31">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-31.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM32">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-32.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM33">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-33.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM34">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-34.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM35">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-35.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM36">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-36.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM37">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-37.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM38">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-38.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM39">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-39.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM40">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-40.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM41">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-41.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM42">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-42.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM43">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-43.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM44">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-44.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM45">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-45.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM46">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-46.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM47">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-47.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM48">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-48.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM49">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-49.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM50">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-50.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM51">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-51.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM52">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-52.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM53">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-53.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM54">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-54.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM55">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-55.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM56">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-56.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM57">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-57.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM58">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-58.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM59">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-59.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM60">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-60.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM61">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-61.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM62">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-62.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM63">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-63.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM64">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-64.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM65">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-65.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM66">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-66.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM67">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-67.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM68">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-68.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM69">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-69.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM70">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-70.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM71">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-71.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM72">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-72.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM73">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-73.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM74">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-74.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM75">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-75.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM76">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-76.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM77">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-77.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM78">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-78.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM79">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-79.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM80">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-80.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM81">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-81.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM82">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-82.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM83">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-83.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM84">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-84.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM85">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-85.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM86">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-86.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM87">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-87.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM88">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-88.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM89">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-89.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM90">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-90.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM91">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-91.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM92">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-92.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM93">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-93.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM94">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-94.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM95">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-95.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM96">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-96.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM97">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-97.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM98">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-98.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM99">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-99.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM100">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-100.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM101">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-101.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM102">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-102.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM103">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-103.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM104">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-104.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM105">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-105.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM106">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-106.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM107">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-107.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM108">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-108.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM109">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-109.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM110">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-110.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM111">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-111.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM112">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-112.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM113">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-113.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM114">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-114.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM115">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-115.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM116">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-116.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM117">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-117.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM118">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-118.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM119">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-119.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM120">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-120.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM121">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-121.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM122">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-122.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM122a">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-122a.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM123">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-123.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM124">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-124.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM125">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-125.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM126">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-126.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM127">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-127.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM128">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-128.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM129">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-129.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM130">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-130.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM131">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-131.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM132">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-132.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM133">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-133.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM134">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-134.jpg"/>
              </value>
            </observationMedia>
          </component>
          <component>
            <observationMedia ID="MM135">
              <text>Figure</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-135.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
      <component>
        <section>
          <id root="ba6bface-4813-4524-8b4b-aa8e4617677d"/>
          <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
          <title>PRINCIPAL DISPLAY PANEL - 4 Ampule Pouch Carton</title>
          <text>
            <paragraph>							TYVASO<sup>®</sup>
              <br/>							(treprostinil) 							<br/>							INHALATION<br/>SOLUTION 						</paragraph>
            <paragraph>Treprostinil 1.74 mg / 2.9 mL (0.6 mg/mL)</paragraph>
            <paragraph>Four 2.9 mL ampules</paragraph>
            <paragraph>							For oral inhalation use only 						</paragraph>
            <paragraph>See package insert and<br/>Instructions For Use manual<br/>for dosage and administration</paragraph>
            <renderMultiMedia referencedObject="MM136"/>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM136">
              <text>Principal Display Panel - 4 Ampule Pouch Carton</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-136.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
      <component>
        <section>
          <id root="6a4685e3-32db-485d-9008-106d934ae12d"/>
          <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
          <title>PRINCIPAL DISPLAY PANEL - 28 Ampule Pouch Carton</title>
          <text>
            <paragraph>
              <content styleCode="italics">TYVASO<sup>®</sup>
              </content>
              <br/>
              <content styleCode="italics">(treprostinil)</content>
              <br/>
              <content styleCode="italics">INHALATION<br/>SOLUTION</content>
            </paragraph>
            <paragraph>Treprostinil 1.74 mg / 2.9 mL (0.6 mg/mL)</paragraph>
            <paragraph>Seven foil pouches each containing four<br/>2.9 mL ampules</paragraph>
            <paragraph>							For oral inhalation use only 						</paragraph>
            <paragraph>See package insert and<br/>Instructions For Use manual<br/>for dosage and administration.</paragraph>
            <renderMultiMedia referencedObject="MM137"/>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM137">
              <text>PRINCIPAL DISPLAY PANEL - 28 Ampule Pouch Carton</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-137.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
      <component>
        <section>
          <id root="8f15f41f-f72b-4fbe-afa0-6c1c3385a7a8"/>
          <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
          <title>PRINCIPAL DISPLAY PANEL - Patient Starter Kit</title>
          <text>
            <paragraph>TYVASO Inhalation System</paragraph>
            <paragraph>Patient Starter Kit</paragraph>
            <paragraph>TYVASO<sup>®</sup>
              <br/>(treprostinil) <br/> INHALATION<br/>SOLUTION</paragraph>
            <paragraph>Treprostinil 1.74 mg/2.9 mL (0.6 mg/mL)</paragraph>
            <paragraph>TYVASO is for oral inhalation use only and is intended for administration with the TYVASO Inhalation System. <br/> See package insert and Instructions for Use manual for dosage and administration.</paragraph>
            <table styleCode="Noautorules" width="90%">
              <col align="left" valign="middle" width="44%"/>
              <col align="center" valign="middle" width="8%"/>
              <col align="left" valign="middle" width="40%"/>
              <col align="center" valign="middle" width="8%"/>
              <tbody>
                <tr>
                  <td>CONTENTS</td>
                  <td>QTY</td>
                  <td>CONTENTS</td>
                  <td>QTY</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>28 ampule carton of TYVASO <br/> (seven foil pouches, each containing four 2.9 mL ampules)</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>AC wall plugs</item>
                    </list>
                  </td>
                  <td>2</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>TYVASO Inhalation Device</item>
                    </list>
                  </td>
                  <td>2</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Water level cup</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>TYVASO Inhalation System Instructions for Use manual</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Plugs for storage between treatment sessions</item>
                    </list>
                  </td>
                  <td>2</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Treatment Tracker</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Carrying case</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Sets of Dome assembly, Inhalation piece, <br/> Mouthpiece, and 2 Filter shells</item>
                    </list>
                  </td>
                  <td>2</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Distilled water carrier</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Medicine cups</item>
                    </list>
                  </td>
                  <td>32</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Filter membranes</item>
                    </list>
                  </td>
                  <td>65</td>
                </tr>
              </tbody>
            </table>
            <paragraph>Each ampule of TYVASO contains: treprostinil 1.74 mg. Each ampule also contains 18.9 mg sodium chloride, <br/> 18.3 mg sodium citrate dihydrate, 0.6 mg sodium hydroxide, 11.7 mg 1N hydrochloric acid, and water for injection. <br/> Hydrochloric acid and sodium hydroxide may have been added to adjust pH.</paragraph>
            <list>
              <item>
                <caption>+</caption> One new ampule should be used each day. Each ampule of TYVASO (once opened and transferred to the <br/> medicine cup) should remain in the device for no more than 1 day. Any remaining TYVASO and the medicine <br/> cup should be discarded at the end of each day.</item>
              <item>
                <caption>+</caption>Once a foil pouch is opened, use ampules within 7 days.</item>
              <item>
                <caption>+</caption>Store unused ampules of TYVASO in the foil pouch until use, protected from light.</item>
              <item>
                <caption>+</caption>Store at 25°C (77°F); excursions permitted to 15°C to 30°C (59°F to 86°F) [see USP Controlled Room Temperature].</item>
            </list>
            <paragraph>Patient Starter Kit For Single Patient Use Only. <br/> Keep out of the reach of children. <br/> NDC 66302-206-01 <br/>Rx only</paragraph>
            <paragraph>Manufactured by United Therapeutics Corporation <br/> Durham, NC 27713</paragraph>
            <paragraph>United <br/>Therapeutics <br/> A PUBLIC BENEFIT CORPORATION</paragraph>
            <paragraph>102129 <br/>Rev. 01/2026</paragraph>
            <paragraph>MATERIAL: <br/> 102132</paragraph>
            <paragraph>LOT: <br/> 2102958</paragraph>
            <paragraph>EXP: <br/> 2028 – AUG</paragraph>
            <paragraph>Device SN#1: <br/> 25083422</paragraph>
            <paragraph>Device SN#2: <br/> 25083257</paragraph>
            <renderMultiMedia referencedObject="MM138"/>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM138">
              <text>PRINCIPAL DISPLAY PANEL - Patient Starter Kit</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-138.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
      <component>
        <section>
          <id root="9cd9bc5a-9b3a-4c68-ac8a-b310f27c2f5a"/>
          <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
          <title>PRINCIPAL DISPLAY PANEL - Refill Kit</title>
          <text>
            <paragraph>TYVASO Inhalation System<br/>Refill Kit</paragraph>
            <paragraph>TYVASO<sup>®</sup>
              <br/>(treprostinil)<br/>INHALATION<br/>SOLUTION</paragraph>
            <paragraph>Treprostinil 1.74 mg/2.9 mL (0.6 mg/mL)</paragraph>
            <paragraph>TYVASO is for oral inhalation use only and is intended for administration with the TYVASO Inhalation System.<br/>See package insert and Instructions for Use manual for dosage and administration.</paragraph>
            <table styleCode="Noautorules" width="90%">
              <col align="left" valign="middle" width="44%"/>
              <col align="center" valign="middle" width="8%"/>
              <col align="left" valign="middle" width="40%"/>
              <col align="center" valign="middle" width="8%"/>
              <tbody>
                <tr>
                  <td>CONTENTS</td>
                  <td>QTY</td>
                  <td>CONTENTS</td>
                  <td>QTY</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>28 ampule carton of TYVASO<br/>(seven foil pouches, each containing four 2.9 mL ampules)</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Filter membranes</item>
                    </list>
                  </td>
                  <td>65</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Set of Dome assembly, Inhalation piece,<br/>Mouthpiece, and 2 Filter shells</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Plugs for storage between treatment sessions</item>
                    </list>
                  </td>
                  <td>2</td>
                </tr>
                <tr>
                  <td>
                    <list>
                      <item>
                        <caption>+</caption>Medicine cups</item>
                    </list>
                  </td>
                  <td>32</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Treatment Tracker</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
              </tbody>
            </table>
            <paragraph>Each ampule of TYVASO contains: treprostinil 1.74 mg. Each ampule also contains 18.9 mg sodium chloride,<br/>18.3 mg sodium citrate dihydrate, 0.6 mg sodium hydroxide, 11.7 mg 1N hydrochloric acid, and water for injection.<br/>Hydrochloric acid and sodium hydroxide may have been added to adjust pH.</paragraph>
            <list>
              <item>
                <caption>+</caption>One new ampule should be used each day. Each ampule of TYVASO (once opened and transferred to the medicine<br/>cup) should remain in the device for no more than 1 day. Any remaining TYVASO and the medicine cup should be<br/>discarded at the end of each day.</item>
              <item>
                <caption>+</caption>Once a foil pouch is opened, use ampules within 7 days.</item>
              <item>
                <caption>+</caption>Store unused ampules of TYVASO in the foil pouch until use, protected from light.</item>
              <item>
                <caption>+</caption>Store at 25°C (77°F); excursions permitted to 15°C to 30°C (59°F to 86°F) [see USP Controlled Room Temperature].</item>
            </list>
            <paragraph>Keep out of the reach of children.</paragraph>
            <paragraph>NDC 66302-206-02<br/>Rx only</paragraph>
            <paragraph>Manufactured by United Therapeutics Corporation<br/>Durham, NC 27713</paragraph>
            <paragraph>United<br/>Therapeutics<br/>A PUBLIC BENEFIT CORPORATION</paragraph>
            <paragraph>102136<br/>Rev. 01/2026</paragraph>
            <paragraph>LOT XXXXXXX<br/>EXP YYYY-MMM<br/>GTIN XXXXXXXXXXXXXX<br/>S/N XXXXXXXXXXXX</paragraph>
            <renderMultiMedia referencedObject="MM139"/>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM139">
              <text>PRINCIPAL DISPLAY PANEL - Refill Kit</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-139.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
      <component>
        <section>
          <id root="cde43651-b68f-469b-aa5d-ee9d3ab6aaa9"/>
          <code code="51945-4" codeSystem="2.16.840.1.113883.6.1" displayName="PACKAGE LABEL.PRINCIPAL DISPLAY PANEL"/>
          <title>PRINCIPAL DISPLAY PANEL - Institutional Starter Kit</title>
          <text>
            <paragraph>TYVASO Inhalation System <br/> Institutional Starter Kit</paragraph>
            <paragraph>TYVASO<sup>®</sup>
              <br/> (treprostinil) <br/> INHALATION <br/> SOLUTION</paragraph>
            <paragraph>Treprostinil 1.74 mg/2.9 mL (0.6 mg/mL)</paragraph>
            <paragraph>TYVASO is for oral inhalation use only and is intended for administration with the TYVASO Inhalation System. <br/> See package insert and Instructions for Use manual for dosage and administration.</paragraph>
            <table styleCode="Noautorules" width="90%">
              <col align="left" valign="middle" width="42%"/>
              <col align="center" valign="middle" width="8%"/>
              <col align="left" valign="middle" width="42%"/>
              <col align="center" valign="middle" width="8%"/>
              <tbody>
                <tr>
                  <td>CONTENTS</td>
                  <td>QTY</td>
                  <td>CONTENTS</td>
                  <td>QTY</td>
                </tr>
                <tr>
                  <td valign="middle">
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>4 ampule carton of TYVASO <br/> (one foil pouch containing four 2.9 mL ampules)</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>AC wall plugs</item>
                    </list>
                  </td>
                  <td>2</td>
                </tr>
                <tr>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>TYVASO Inhalation Device</item>
                    </list>
                  </td>
                  <td>2</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Water level cup</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
                <tr>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>TYVASO Inhalation System Instructions for Use manual</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Plugs for storage between treatment sessions</item>
                    </list>
                  </td>
                  <td>2</td>
                </tr>
                <tr>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Treatment Tracker</item>
                    </list>
                  </td>
                  <td>1</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Carrying case</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
                <tr>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Sets of Dome assembly, Inhalation piece, <br/> Mouthpiece, and 2 Filter shells</item>
                    </list>
                  </td>
                  <td>2</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Distilled water carrier</item>
                    </list>
                  </td>
                  <td>1</td>
                </tr>
                <tr>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Medicine cups</item>
                    </list>
                  </td>
                  <td>32</td>
                  <td>
                    <list listType="unordered">
                      <item>
                        <caption>+</caption>Filter membranes</item>
                    </list>
                  </td>
                  <td>65</td>
                </tr>
              </tbody>
            </table>
            <paragraph>Each ampule of TYVASO contains: treprostinil 1.74 mg. Each ampule also contains 18.9 mg sodium chloride, <br/> 18.3 mg sodium citrate dihydrate, 0.6 mg sodium hydroxide, 11.7 mg 1N hydrochloric acid, and water for injection. <br/> Hydrochloric acid and sodium hydroxide may have been added to adjust pH.</paragraph>
            <list listType="unordered">
              <item>
                <caption>+</caption>One new ampule should be used each day. Each ampule of TYVASO (once opened and transferred to the <br/> medicine cup) should remain in the device for no more than 1 day. Any remaining TYVASO and the medicine <br/> cup should be discarded at the end of each day.</item>
              <item>
                <caption>+</caption>Once a foil pouch is opened, use ampules within 7 days.</item>
              <item>
                <caption>+</caption>Store unused ampules of TYVASO in the foil pouch until use, protected from light.</item>
              <item>
                <caption>+</caption>Store at 25°C (77°F); excursions permitted to 15°C to 30°C (59°F to 86°F) [see USP Controlled Room Temperature].</item>
            </list>
            <paragraph>Institutional Starter Kit For Single Patient Use Only. <br/> Keep out of the reach of children. <br/> NDC 66302-206-04 <br/> Rx only</paragraph>
            <paragraph>Manufactured by United Therapeutics Corporation <br/> Durham, NC 27713</paragraph>
            <paragraph>United <br/> Therapeutics <br/> A PUBLIC BENEFIT CORPORATION</paragraph>
            <paragraph>102130 <br/> Rev. 01/2026</paragraph>
            <paragraph>MATERIAL: <br/> 102133</paragraph>
            <paragraph>LOT: <br/> 2102764</paragraph>
            <paragraph>EXP: 2027 <br/>– SEP</paragraph>
            <paragraph>Device SN#1: <br/> 25078743</paragraph>
            <paragraph>Device SN#2: <br/> 25078749</paragraph>
            <renderMultiMedia referencedObject="MM140"/>
          </text>
          <effectiveTime value="20220506"/>
          <component>
            <observationMedia ID="MM140">
              <text>PRINCIPAL DISPLAY PANEL - Institutional Starter Kit</text>
              <value mediaType="image/jpeg" xsi:type="ED">
                <reference value="tyvaso-140.jpg"/>
              </value>
            </observationMedia>
          </component>
        </section>
      </component>
    </structuredBody>
  </component>
</document>